The residence time of a fluid parcel is the total time that the parcel has spent inside a control volume (e.g.: a chemical reactor, a lake, a human body). The residence time of a set of parcels is quantified in terms of the frequency distribution of the residence time in the set, which is known as residence time distribution (RTD), or in terms of its average, known as mean residence time.
Residence time plays an important role in chemistry and especially in environmental science and pharmacology. Under the name lead time or waiting time it plays a central role respectively in supply chain management and queueing theory, where the material that flows is usually discrete instead of continuous.
The concept of residence time originated in models of chemical reactors. The first such model was an axial dispersion model by Irving Langmuir in 1908. This received little attention for 45 years; other models were developed such as the plug flow reactor model and the continuous stirred-tank reactor, and the concept of a washout function (representing the response to a sudden change in the input) was introduced. Then, in 1953, Peter Danckwerts resurrected the axial dispersion model and formulated the modern concept of residence time.[1]
The time that a particle of fluid has been in a control volume (e.g. a reservoir) is known as its age. In general, each particle has a different age. The frequency of occurrence of the age
\tau
t
I
At the moment a particle leaves the control volume, its age is the total time that the particle has spent inside the control volume, which is known as its residence time. The frequency of occurrence of the age
\tau
t
E
Both distributions are assumed to be positive and to have unitary integral along the age:
infty | |
\int | |
0 |
E(\tau,t)d\tau=
infty | |
\int | |
0 |
I(\tau,t)d\tau=1
In the case of steady flow, the distributions are assumed to be independent of time, that is
\partialtE=\partialtI=0 \forallt
If the flow is steady (but a generalization to non-steady flow is possible) and is conservative, then the exit age distribution and the internal age distribution can be related one to the other:
\left.\begin{aligned}
\partialI | = | |
\partialt |
dm | |
dt |
=0&\\[4pt] fin=fout=f& \end{aligned} \right\}\impliesfE=-m
\partialI | |
\partial\tau |
Distributions other than
E
I
t
\tau
W
\tau | |
W(\tau,t)=1-\int | |
0 |
E(s,t)ds
The mean age of all the particles inside the control volume at time t is the first moment of the age distribution:
\taua(t)=
infty | |
\int | |
0 |
\tauI(\tau,t)d\tau
The mean residence time or mean transit time, that is the mean age of all the particles leaving the control volume at time t, is the first moment of the residence time distribution:
\taut(t)=
infty | |
\int | |
0 |
\tauE(\tau,t)d\tau.
The mean age and the mean transit time generally have different values, even in stationary conditions:
\taua<\taut
\taua=\taut
\taua>\taut
If the flow is steady and conservative, the mean residence time equals the ratio between the amount of fluid contained in the control volume and the flow rate through it:
\left.\begin{aligned}
\partialI | = | |
\partialt |
dm | |
dt |
=0&\\ fin=fout=f& \end{aligned} \right\}\implies\taut=
m | |
f |
The residence time of a specific compound in a mixture equals the turnover time (that of the compound, as well as that of the mixture) only if the compound does not take part in any chemical reaction (otherwise its flow is not conservative) and its concentration is uniform.
Although the equivalence between the residence time and the ratio
m/f
Design equations are equations relating the space time to the fractional conversion and other properties of the reactor. Different design equations have been derived for different types of the reactor and depending on the reactor the equation more or less resemble that describing the average residence time. Often design equations are used to minimize the reactor volume or volumetric flow rate required to operate a reactor.[4]
In an ideal plug flow reactor (PFR) the fluid particles leave in the same order they arrived, not mixing with those in front and behind. Therefore, the particles entering at time t will exit at time t + T, all spending a time T inside the reactor. The residence time distribution will be then a Dirac delta function delayed by T:
E(\tau)=\delta(\tau-T)
The RTD of a real reactor deviates from that of an ideal reactor, depending on the hydrodynamics within the vessel. A non-zero variance indicates that there is some dispersion along the path of the fluid, which may be attributed to turbulence, a non-uniform velocity profile, or diffusion. If the mean of the distribution is earlier than the expected time T it indicates that there is stagnant fluid within the vessel. If the RTD curve shows more than one main peak it may indicate channeling, parallel paths to the exit, or strong internal circulation.
In PFRs, reactants enter the reactor at one end and react as they move down the reactor. Consequently, the reaction rate is dependent on the concentrations which vary along the reactor requiring the inverse of the reaction rate to be integrated over the fractional conversion.
\tau=CAO\int
1 | |
(-rA) |
dfA
Batch reactors are reactors in which the reactants are put in the reactor at time 0 and react until the reaction is stopped. Consequently, the space time is the same as the average residence time in a batch reactor.
\tau=NAO\int
1 | |
(-rA)VR |
dfA
In an ideal continuous stirred-tank reactor (CSTR), the flow at the inlet is completely and instantly mixed into the bulk of the reactor. The reactor and the outlet fluid have identical, homogeneous compositions at all times. The residence time distribution is exponential:
E(\tau)=
1 | \exp\left( | |
T |
-\tau | |
T |
\right).
In reality, it is impossible to obtain such rapid mixing, as there is necessarily a delay between any molecule passing through the inlet and making its way to the outlet, and hence the RTD of a real reactor will deviate from the ideal exponential decay, especially in the case of large reactors. For example, there will be some finite delay before E reaches its maximum value and the length of the delay will reflect the rate of mass transfer within the reactor. Just as was noted for a plug-flow reactor, an early mean will indicate some stagnant fluid within the vessel, while the presence of multiple peaks could indicate channeling, parallel paths to the exit, or strong internal circulation. Short-circuiting fluid within the reactor would appear in an RTD curve as a small pulse of concentrated tracer that reaches the outlet shortly after injection.Reactants continuously enter and leave a tank where they are mixed. Consequently, the reaction proceeds at a rate dependent on the outlet concentration:
\tau=
CAin-CAout | |
-rA |
In a laminar flow reactor, the fluid flows through a long tube or parallel plate reactor and the flow is in layers parallel to the walls of the tube. The velocity of the flow is a parabolic function of radius. In the absence of molecular diffusion, the RTD is[5]
E(\tau)=\begin{cases} 0&\tau\leqT/2\\[5pt] \dfrac{T2}{2\tau3}&\tau>T/2. \end{cases}
Recycle reactors are PFRs with a recycle loop. Consequently, they behave like a hybrid between PFRs and CSTRs.
\tau=CAO(R+1)\int
1 | |
(-rA) |
dfA
In all of these equations :
-rA
In some reactions the reactants and the products have significantly different densities. Consequently, as the reaction proceeds the volume of the reaction changes. This variable volume adds terms to the design equations. Taking this volume change into consideration the volume of the reaction becomes:
VR=VRinitial(1-\deltaAfA)
Plugging this into the design equations results in the following equations:
\tau=NAO\int
1 | |
(-rA)VR(1-\deltaAfA) |
dfA
\tau=CAO\int
1 | |
(-rA)(1-\deltaAfA) |
dfA
\tau=
CAin-CAout | |
-rAF(1-\deltaAfA) |
Generally, when reactions take place in the liquid and solid phases the change in volume due to reaction is not significant enough that it needs to be taken into account. Reactions in the gas phase often have significant changes in volume and in these cases one should use these modified equations.
Residence time distributions are measured by introducing a non-reactive tracer into the system at the inlet. Its input concentration is changed according to a known function and the output concentration measured. The tracer should not modify the physical characteristics of the fluid (equal density, equal viscosity) or the hydrodynamic conditions and it should be easily detectable.[6] In general, the change in tracer concentration will either be a pulse or a step. Other functions are possible, but they require more calculations to deconvolute the RTD curve.
This method required the introduction of a very small volume of concentrated tracer at the inlet of the reactor, such that it approaches the Dirac delta function.[7] [5] Although an infinitely short injection cannot be produced, it can be made much smaller than the mean residence time of the vessel. If a mass of tracer,
M
V
\tau
C(t)
E(t)=
C(t) | |||||||||
|
The concentration of tracer in a step experiment at the reactor inlet changes abruptly from 0 to
C0
C0
F(t)
F(t)=
C(t) | |
C0 |
.
The step- and pulse-responses of a reactor are related by the following:
F(t)=
t | |
\int | |
0 |
E(t')dt' E(t)=
dF(t) | |
dt |
A step experiment is often easier to perform than a pulse experiment, but it tends to smooth over some of the details that a pulse response could show. It is easy to numerically integrate an experimental pulse response to obtain a very high-quality estimate of the step response, but the reverse is not the case because any noise in the concentration measurement will be amplified by numeric differentiation.
In chemical reactors, the goal is to make components react with a high yield. In a homogeneous, first-order reaction, the probability that an atom or molecule will react depends only on its residence time:
PR=\exp\left(-kt\right)
k
a
\overline{PR
If the reaction is more complicated, then the output is not uniquely determined by the RTD. It also depends on the degree of micromixing, the mixing between molecules that entered at different times. If there is no mixing, the system is said to be completely segregated, and the output can be given in the form
aout=
infty | |
\int | |
0 |
abatch(t)E(t)dt.
The RTD of chemical reactors can be obtained by CFD simulations. The very same procedure that is performed in experiments can be followed. A pulse of inert tracer particles (during a very short time) is injected into the reactor. The linear motion of tracer particles is governed by Newton's second law of motion and a one-way coupling is stablished between fluid and tracers. In one-way coupling, fluid affects tracer motion by drag force while tracer does not affect fluid. The size and density of tracers are chosen so small that the time constant of tracers becomes very small. In this way, tracer particles exactly follow the same path as the fluid does.[8]
Hydraulic residence time (HRT) is an important factor in the transport of environmental toxins or other chemicals through groundwater. The amount of time that a pollutant spends traveling through a delineated subsurface space is related to the saturation and the hydraulic conductivity of the soil or rock.[9] Porosity is another significant contributing factor to the mobility of water through the ground (e.g. toward the water table). The intersection between pore density and size determines the degree or magnitude of the flow rate through the media. This idea can be illustrated by a comparison of the ways water moves through clay versus gravel. The retention time through a specified vertical distance in clay will be longer than through the same distance in gravel, even though they are both characterized as high porosity materials. This is because the pore sizes are much larger in gravel media than in clay, and so there is less hydrostatic tension working against the subsurface pressure gradient and gravity.
Groundwater flow is important parameter for consideration in the design of waste rock basins for mining operations. Waste rock is heterogeneous material with particles varying from boulders to clay-sized particles, and it contains sulfidic pollutants which must be controlled such that they do not compromise the quality of the water table and also so the runoff does not create environmental problems in the surrounding areas. Aquitards are clay zones that can have such a degree of impermeability that they partially or completely retard water flow.[10] These clay lenses can slow or stop seepage into the water table, although if an aquitard is fractured and contaminated then it can become a long-term source of groundwater contamination due to its low permeability and high HRT.
See also: Activated sludge and Waste stabilization pond. Primary treatment for wastewater or drinking water includes settling in a sedimentation chamber to remove as much of the solid matter as possible before applying additional treatments. The amount removed is controlled by the hydraulic residence time (HRT). When water flows through a volume at a slower rate, less energy is available to keep solid particles entrained in the stream and there is more time for them to settle to the bottom. Typical HRTs for sedimentation basins are around two hours, although some groups recommend longer times to remove micropollutants such as pharmaceuticals and hormones.[11]
Disinfection is the last step in the tertiary treatment of wastewater or drinking water. The types of pathogens that occur in untreated water include those that are easily killed like bacteria and viruses, and those that are more robust such as protozoa and cysts. The disinfection chamber must have a long enough HRT to kill or deactivate all of them.
See also: Surface science. Atoms and molecules of gas or liquid can be trapped on a solid surface in a process called adsorption. This is an exothermic process involving a release of heat, and heating the surface increases the probability that an atom will escape within a given time. At a given temperature
T
\tau=\tau0\exp\left(
Ea | |
RT |
\right),
R
Ea
\tau0
10-12
In vacuum technology, the residence time of gases on the surfaces of a vacuum chamber can determine the pressure due to outgassing. If the chamber can be heated, the above equation shows that the gases can be "baked out"; but if not, then surfaces with a low residence time are needed to achieve ultra-high vacuums.[13]
See also: Lake retention time. In environmental terms, the residence time definition is adapted to fit with ground water, the atmosphere, glaciers, lakes, streams, and oceans. More specifically it is the time during which water remains within an aquifer, lake, river, or other water body before continuing around the hydrological cycle. The time involved may vary from days for shallow gravel aquifers to millions of years for deep aquifers with very low values for hydraulic conductivity. Residence times of water in rivers are a few days, while in large lakes residence time ranges up to several decades. Residence times of continental ice sheets is hundreds of thousands of years, of small glaciers a few decades.
Ground water residence time applications are useful for determining the amount of time it will take for a pollutant to reach and contaminate a ground water drinking water source and at what concentration it will arrive. This can also work to the opposite effect to determine how long until a ground water source becomes uncontaminated via inflow, outflow, and volume. The residence time of lakes and streams is important as well to determine the concentration of pollutants in a lake and how this may affect the local population and marine life.
Hydrology, the study of water, discusses the water budget in terms of residence time. The amount of time that water spends in each different stage of life (glacier, atmosphere, ocean, lake, stream, river), is used to show the relation of all of the water on the earth and how it relates in its different forms.
A large class of drugs are enzyme inhibitors that bind to enzymes in the body and inhibit their activity. In this case it is the drug-target residence time (the length of time the drug stays bound to the target) that is of interest. The residence time is defined as the reciprocal value of the koff rate constant (residence time = 1/koff). Drugs with long residence times are desirable because they remain effective for longer and therefore can be used in lower doses.[14] This residence time is determined by the kinetics of the interaction, such as how complementary the shape and charges of the target and drug are and whether outside solvent molecules are kept out of the binding site (thereby preventing them from breaking any bonds formed),[15] and is proportional to the half-life of the chemical dissociation.[16] One way to measure the residence time is in a preincubation-dilution experiment where a target enzyme is incubated with the inhibitor, allowed to approach equilibrium, then rapidly diluted. The amount of product is measured and compared to a control in which no inhibitor is added.[14]
Residence time can also refer to the amount of time that a drug spends in the part of the body where it needs to be absorbed. The longer the residence time, the more of it can be absorbed. If the drug is delivered in an oral form and destined for the upper intestines, it usually moves with food and its residence time is roughly that of the food. This generally allows 3 to 8 hours for absorption.[17] If the drug is delivered through a mucous membrane in the mouth, the residence time is short because saliva washes it away. Strategies to increase this residence time include bioadhesive polymers, gums, lozenges and dry powders.[17]
In size-exclusion chromatography, the residence time of a molecule is related to its volume, which is roughly proportional to its molecular weight. Residence times also affect the performance of continuous fermentors.[1]
Biofuel cells utilize the metabolic processes of anodophiles (electronegative bacteria) to convert chemical energy from organic matter into electricity.[18] [19] [20] A biofuel cell mechanism consists of an anode and a cathode that are separated by an internal proton exchange membrane (PEM) and connected in an external circuit with an external load. Anodophiles grow on the anode and consume biodegradable organic molecules to produce electrons, protons, and carbon dioxide gas, and as the electrons travel through the circuit they feed the external load. The HRT for this application is the rate at which the feed molecules are passed through the anodic chamber. This can be quantified by dividing the volume of the anodic chamber by the rate at which the feed solution is passed into the chamber. The hydraulic residence time (HRT) affects the substrate loading rate of the microorganisms that the anodophiles consume, which affects the electrical output.[21] Longer HRTs reduce substrate loading in the anodic chamber which can lead to reduced anodophile population and performance when there is a deficiency of nutrients. Shorter HRTs support the development of non-exoelectrogenous bacteria which can reduce the Coulombic efficiency electrochemical performance of the fuel cell if the anodophiles must compete for resources or if they do not have ample time to effectively degrade nutrients.