A parametric oscillator is a driven harmonic oscillator in which the oscillations are driven by varying some parameters of the system at some frequencies, typically different from the natural frequency of the oscillator. A simple example of a parametric oscillator is a child pumping a playground swing by periodically standing and squatting to increase the size of the swing's oscillations.[1] [2] [3] The child's motions vary the moment of inertia of the swing as a pendulum. The "pump" motions of the child must be at twice the frequency of the swing's oscillations. Examples of parameters that may be varied are the oscillator's resonance frequency
\omega
\beta
Parametric oscillators are used in several areas of physics. The classical varactor parametric oscillator consists of a semiconductor varactor diode connected to a resonant circuit or cavity resonator. It is driven by varying the diode's capacitance by applying a varying bias voltage. The circuit that varies the diode's capacitance is called the "pump" or "driver". In microwave electronics, waveguide/YAG-based parametric oscillators operate in the same fashion. Another important example is the optical parametric oscillator, which converts an input laser light wave into two output waves of lower frequency (
\omegas,\omegai
When operated at pump levels below oscillation, the parametric oscillator can amplify a signal, forming a parametric amplifier (paramp). Varactor parametric amplifiers were developed as low-noise amplifiers in the radio and microwave frequency range. The advantage of a parametric amplifier is that it has much lower noise than an amplifier based on a gain device like a transistor or vacuum tube. This is because in the parametric amplifier a reactance is varied instead of a (noise-producing) resistance. They are used in very low noise radio receivers in radio telescopes and spacecraft communication antennas.[4]
Parametric resonance occurs in a mechanical system when a system is parametrically excited and oscillates at one of its resonant frequencies. Parametric excitation differs from forcing since the action appears as a time varying modification on a system parameter.
Parametric oscillations were first noticed in mechanics. Michael Faraday (1831) was the first to notice oscillations of one frequency being excited by forces of double the frequency, in the crispations (ruffled surface waves) observed in a wine glass excited to "sing".[5] Franz Melde (1860) generated parametric oscillations in a string by employing a tuning fork to periodically vary the tension at twice the resonance frequency of the string.[6] Parametric oscillation was first treated as a general phenomenon by Rayleigh (1883,1887).[7] [8] [9]
One of the first to apply the concept to electric circuits was George Francis FitzGerald, who in 1892 tried to excite oscillations in an LC circuit by pumping it with a varying inductance provided by a dynamo.[10] [11] Parametric amplifiers (paramps) were first used in 1913-1915 for radio telephony from Berlin to Vienna and Moscow, and were predicted to have a useful future (Ernst Alexanderson, 1916).[12] These early parametric amplifiers used the nonlinearity of an iron-core inductor, so they could only function at low frequencies.
In 1948 Aldert van der Ziel pointed out a major advantage of the parametric amplifier: because it used a variable reactance instead of a resistance for amplification it had inherently low noise. A parametric amplifier used as the front end of a radio receiver could amplify a weak signal while introducing very little noise. In 1952 Harrison Rowe at Bell Labs extended some 1934 mathematical work on pumped oscillations by Jack Manley and published the modern mathematical theory of parametric oscillations, the Manley-Rowe relations.
The varactor diode invented in 1956 had a nonlinear capacitance that was usable into microwave frequencies. The varactor parametric amplifier was developed by Marion Hines in 1956 at Western Electric.[13] At the time it was invented microwaves were just being exploited, and the varactor amplifier was the first semiconductor amplifier at microwave frequencies.[13] It was applied to low noise radio receivers in many areas, and has been widely used in radio telescopes, satellite ground stations, and long-range radar. It is the main type of parametric amplifier used today. Since that time parametric amplifiers have been built with other nonlinear active devices such as Josephson junctions.
The technique has been extended to optical frequencies in optical parametric oscillators and amplifiers which use nonlinear crystals as the active element.
A parametric oscillator is a harmonic oscillator whose physical properties vary with time. The equation of such an oscillator is
d2x | |
dt2 |
+\beta(t)
dx | |
dt |
+\omega2(t)x=0
This equation is linear in
x(t)
\omega2
\beta
\beta(t)
\omega2(t)
T
If the parameters vary at roughly twice the natural frequency of the oscillator (defined below), the oscillator phase-locks to the parametric variation and absorbs energy at a rate proportional to the energy it already has. Without a compensating energy-loss mechanism provided by
\beta
A familiar experience of both parametric and driven oscillation is playing on a swing.[1] [2] [3] Rocking back and forth pumps the swing as a driven harmonic oscillator, but once moving, the swing can also be parametrically driven by alternately standing and squatting at key points in the swing arc. This changes moment of inertia of the swing and hence the resonance frequency, and children can quickly reach large amplitudes provided that they have some amplitude to start with (e.g., get a push). Standing and squatting at rest, however, leads nowhere.
We begin by making a change of variable
q(t) \stackrel{def
where
D(t)
D(t) \stackrel{def
This change of variable eliminates the damping term in the differential equation, reducing it to
d2q | |
dt2 |
+\Omega2(t)q=0
where the transformed frequency is defined as
\Omega2(t) \stackrel{def
In general, the variations in damping and frequency are relatively small perturbations
\beta(t)=\omega0[b+g(t)]
\omega2(t)=
2 | |
\omega | |
0 |
[1+h(t)]
where
\omega0
b
\Omega2(t)=
2 | |
\omega | |
n |
[1+f(t)]
where
\omegan
2 | |
\omega | |
n |
\stackrel{def
f(t) \stackrel{def
Thus, our transformed equation can be written as
d2q | |
dt2 |
+
2 | |
\omega | |
n |
[1+f(t)]q=0
The independent variations
g(t)
h(t)
f(t)
Let us assume that
f(t)
f(t)=f0\sin(2\omegapt)
where the pumping frequency
\omegap ≈ \omegan
\omegan
q(t)
q(t)=A(t)\cos(\omegapt)+B(t)\sin(\omegapt)
where the rapidly varying components,
\cos(\omegapt)
\sin(\omegapt)
A(t)
B(t)
We proceed by substituting this solution into the differential equation and considering that both the coefficients in front of
\cos(\omegapt)
\sin(\omegapt)
A(t)
B(t)
A(t)
B(t)
\omegan
2\omegap
dA | |
dt |
=
1 | |
2 |
f0
2 | |
\omega | |
n |
A-\left(
2 | |
\omega | |
p |
-
2 | |
\omega | |
n |
\right)B
2\omegap
dB | |
dt |
=\left(
2 | |
\omega | |
p |
-
2 | |
\omega | |
n |
\right)A-
1 | |
2 |
f0
2 | |
\omega | |
n |
B
This system of linear differential equations with constant coefficients can be decoupled and solved by eigenvalue/eigenvector methods. This yields the solution
\begin{bmatrix} A(t)\ B(t) \end{bmatrix}=c1\vec{V1}
λ1t | |
e |
+c2\vec{V2}
λ2t | |
e |
where
λ1
λ2
1 | \begin{bmatrix} | |
2\omegap |
1 | |
2 |
f0
2 | |
\omega | |
n |
&-\left(
2 | |
\omega | |
p |
-
2 | |
\omega | |
n |
\right)
2 | |
\\ \omega | |
p |
-
2 | |
\omega | |
n |
&-
1 | |
2 |
f0
2 | |
\omega | |
n |
\end{bmatrix}
\vec{V1}
\vec{V2}
c1
c2
λ1,2=\pm
1 | \sqrt{\left( | |
2\omegap |
| |||||||||||||
2 |
\right)2-\left(
2 | |
\omega | |
p |
-
2 | |
\omega | |
n |
\right)2}
If we write the difference between
\omegap
\omegan
\Delta\omega=\omegap-\omegan
\omegap
\omegan
λ1,2=\pm\sqrt{\left(
f0\omegan | |
4 |
\right)2-\Delta\omega2}
If
|\Delta\omega|<
f0\omegan | |
4 |
A(t)
B(t)
λ=\sqrt{\left(
f0\omegan | |
4 |
\right)2-\Delta\omega2}
q(t)
x(t)=q(t)e-D(t)
λt-D(t)
The above derivation may seem like a mathematical sleight-of-hand, so it may be helpful to give an intuitive derivation. The
q
d2q | |
dt2 |
+
2 | |
\omega | |
n |
q=
2 | |
-\omega | |
n |
f(t)q
which represents a simple harmonic oscillator (or, alternatively, a bandpass filter) being driven by a signal
2 | |
-\omega | |
n |
f(t)q
q(t)
Assume that
q(t)=A\cos(\omegapt)
\omegap
f(t)=f0\sin(2\omegapt)
f0\ll1
q(t)f(t)
\omegap
3\omegap
f(t)q(t)=
f0 | |
2 |
A[\sin(\omegapt)+\sin(3\omegapt)]
Being off-resonance, the
3\omegap
\omegap
q(t)
A
q(t)
Expressed in Fourier space, the multiplication
f(t)q(t)
\tilde{F}(\omega)
\tilde{Q}(\omega)
+2\omegap
f(t)
-\omegap
q(t)
+\omegap
2\omegan
-\omegap
+\omegap
q(t)
Parametric resonance is the parametrical resonance phenomenon of mechanical perturbation and oscillation at certain frequencies (and the associated harmonics). This effect is different from regular resonance because it exhibits the instability phenomenon.
Parametric resonance occurs in a mechanical system when a system is parametrically excited and oscillates at one of its resonant frequencies. Parametric excitation differs from forcing since the action appears as a time varying modification on a system parameter. The classical example of parametric resonance is that of the vertically forced pendulum. Parametric resonance takes place when the external excitation frequency equals twice the natural frequency of the system divided by a positive integer
n
h
lO(|h|n)
For small amplitudes and by linearising, the stability of the periodic solution is given by Mathieu's equation:
\ddot{u}+(a+B\cost)u=0
where
u
B \cos(t)
Autoparametric resonance happens in a system with two coupled oscillators, such that the vibrations of one act as parametric resonance on the second. The zero point of the second oscillator becomes unstable, and thus it starts oscillating.[16]
A parametric amplifier is implemented as a mixer. The mixer's gain shows up in the output as amplifier gain. The input weak signal is mixed with a strong local oscillator signal, and the resultant strong output is used in the ensuing receiver stages.
Parametric amplifiers also operate by changing a parameter of the amplifier. Intuitively, this can be understood as follows, for a variable capacitor-based amplifier.Charge
Q
Q=C x V
V=
Q | |
C |
Knowing the above, if a capacitor is charged until its voltage equals the sampled voltage of an incoming weak signal, and if the capacitor's capacitance is then reduced (say, by manually moving the plates further apart), then the voltage across the capacitor will increase. In this way, the voltage of the weak signal is amplified.
If the capacitor is a varicap diode, then "moving the plates" can be done simply by applying time-varying DC voltage to the varicap diode. This driving voltage usually comes from another oscillator—sometimes called a "pump".
The resulting output signal contains frequencies that are the sum and difference of the input signal (f1) and the pump signal (f2): (f1 + f2) and (f1 − f2).
A practical parametric oscillator needs the following connections: one for the "common" or "ground", one to feed the pump, one to retrieve the output, and maybe a fourth one for biasing. A parametric amplifier needs a fifth port to input the signal being amplified. Since a varactor diode has only two connections, it can only be a part of an LC network with four eigenvectors with nodes at the connections. This can be implemented as a transimpedance amplifier, a traveling-wave amplifier or by means of a circulator.
The parametric oscillator equation can be extended by adding an external driving force
E(t)
d2x | |
dt2 |
+\beta(t)
dx | |
dt |
+\omega2(t)x=E(t)
We assume that the damping
D
E
\alphat<D
\beta(t)=\omega0b
\omega0
E(t)=E0\sin\omega0t
d2x | |
dt2 |
+b\omega0
dx | |
dt |
+
2 | |
\omega | |
0 |
\left[1+h0\sin2\omega0t\right]x=E0\sin\omega0t
whose solution is approximately
x(t)=
2E0 | |||||||||
|
\cos\omega0t
As
h0
2b
h0\geq2b
E(t)
If the parameters of any second-order linear differential equation are varied periodically, Floquet analysis shows that the solutions must vary either sinusoidally or exponentially.
The
q
f(t)
f(t)