In electrochemistry, the standard hydrogen electrode (abbreviated SHE), is a redox electrode which forms the basis of the thermodynamic scale of oxidation-reduction potentials. Its absolute electrode potential is estimated to be [1] at 25 °C, but to form a basis for comparison with all other electrochemical reactions, hydrogen's standard electrode potential is declared to be zero volts at any temperature. Potentials of all other electrodes are compared with that of the standard hydrogen electrode at the same temperature.
See also: Nernst equation, Thermodynamic activity and Standard state. The hydrogen electrode is based on the redox half cell corresponding to the reduction of two hydrated protons, into one gaseous hydrogen molecule,
General equation for a reduction reaction:
The reaction quotient of the half-reaction is the ratio between the chemical activities of the reduced form (the reductant,) and the oxidized form (the oxidant,).
Qr=
ared | |
aox |
Considering the redox couple:
at chemical equilibrium, the ratio of the reaction products by the reagents is equal to the equilibrium constant of the half-reaction:
K=
ared | |
aox |
=
| |||||||
|
=
| ||||||||
|
=
| ||||||||
|
where
ared
aox
a | ||
|
a | ||
|
p | ||
|
.
p | ||
|
p | ||
|
=
x | ||
|
⋅ p,
p
More details on managing gas fugacity to get rid of the pressure unit in thermodynamic calculations can be found at thermodynamic activity#Gases. The followed approach is the same as for chemical activity and molar concentration of solutes in solution. In the SHE, pure hydrogen gas (
x | ||
|
=1
p
This redox reaction occurs at a platinized platinum electrode.The electrode is immersed in the acidic solution and pure hydrogen gas is bubbled over its surface. The concentration of both the reduced and oxidised forms of hydrogen are maintained at unity. That implies that the pressure of hydrogen gas is 1 bar (100 kPa) and the activity coefficient of hydrogen ions in the solution is unity. The activity of hydrogen ions is their effective concentration, which is equal to the formal concentration times the activity coefficient. These unit-less activity coefficients are close to 1.00 for very dilute water solutions, but usually lower for more concentrated solutions.
As the general form of the Nernst equation at equilibrium is the following:
and as
\ominus | |
E | |
cell |
=0
The Nernst equation for the SHE becomes:
E=0-{RT\over2F}ln
| ||||||||
E=-2.303{RT\overF}\left(pH+
1 | |
2 |
log
| ||||||
p0 |
\right)
Simply neglecting the pressure unit present in
p | ||
|
E=-2.303{RT\overF}\left(pH+
1 | |
2 |
log
p | ||
|
\right)
And by solving the numerical values for the term
-2.303{RT\overF}=-2.303\left(
8.314 x 298.15 | |
96,485 |
\right)=-0.0591 volts,
E=-0.0591\left(pH+
1 | |
2 |
log
p | ||
|
\right)
As under standard conditions
p | ||
|
=1bar,
log
p | ||
|
=log1=0,
E=-0.0591 pH
This last equation describes the straight line with a negative slope of -0.0591 volt/ pH unit delimiting the lower stability region of water in a Pourbaix diagram where gaseous hydrogen is evolving because of water decomposition.
where:
a | ||
|
=
\gamma | ||
|
\tfrac{C | ||
|
as the system is at chemical equilibrium, hydrogen gas, is also in equilibrium with dissolved hydrogen, and the Nernst equation implicitly takes into account the Henry's law for gas dissolution. Therefore, there is no need to independently consider the gas dissolution process in the system, as it is already de facto included.
During the early development of electrochemistry, researchers used the normal hydrogen electrode as their standard for zero potential. This was convenient because it could actually be constructed by "[immersing] a platinum electrode into a solution of 1 N strong acid and [bubbling] hydrogen gas through the solution at about 1 atm pressure". However, this electrode/solution interface was later changed. What replaced it was a theoretical electrode/solution interface, where the concentration of H+ was 1 M, but the H+ ions were assumed to have no interaction with other ions (a condition not physically attainable at those concentrations). To differentiate this new standard from the previous one, it was given the name 'standard hydrogen electrode'.[2] Finally, there are also reversible hydrogen electrodes (RHEs), which are practical hydrogen electrodes whose potential depends on the pH of the solution.[3]
In summary,
NHE (normal hydrogen electrode): potential of a platinum electrode in 1 M acid solution with 1 bar of hydrogen bubbled through
SHE (standard hydrogen electrode): potential of a platinum electrode in a theoretical ideal solution (the current standard for zero potential for all temperatures)
RHE (reversible hydrogen electrode): a practical hydrogen electrode whose potential depends on the pH of the solution
The choice of platinum for the hydrogen electrode is due to several factors:
The surface of platinum is platinized (i.e., covered with a layer of fine powdered platinum also known as platinum black) to:
Other metals can be used for fabricating electrodes with a similar function such as the palladium-hydrogen electrode.
Because of the high adsorption activity of the platinized platinum electrode, it's very important to protect electrode surface and solution from the presence of organic substances as well as from atmospheric oxygen. Inorganic ions that can be reduced to a lower valency state at the electrode also have to be avoided (e.g.,,). A number of organic substances are also reduced by hydrogen on a platinum surface, and these also have to be avoided.
Cations that can be reduced and deposited on the platinum can be source of interference: silver, mercury, copper, lead, cadmium and thallium.
Substances that can inactivate ("poison") the catalytic sites include arsenic, sulfides and other sulfur compounds, colloidal substances, alkaloids, and material found in biological systems.[5]
The standard redox potential of the deuterium couple is slightly different from that of the proton couple (ca. −0.0044 V vs SHE). Various values in this range have been obtained: −0.0061 V,[6] −0.00431 V,[7] −0.0074 V.
Also difference occurs when hydrogen deuteride (HD, or deuterated hydrogen, DH) is used instead of hydrogen in the electrode.[8]
The scheme of the standard hydrogen electrode: