Optogenetic methods to record cellular activity explained

Optogenetics began with methods to alter neuronal activity with light, using e.g. channelrhodopsins. In a broader sense, optogenetic approaches also include the use of genetically encoded biosensors to monitor the activity of neurons or other cell types by measuring fluorescence or bioluminescence. Genetically encoded calcium indicators (GECIs) are used frequently to monitor neuronal activity, but other cellular parameters such as membrane voltage or second messenger activity can also be recorded optically. The use of optogenetic sensors is not restricted to neuroscience, but plays increasingly important roles in immunology, cardiology and cancer research.

History

The first experiments to measure intracellular calcium levels via protein expression were based on aequorin, a bioluminescent protein from the jellyfish Aequorea. To produce light, however, this enzyme needs the 'fuel' compound coelenteracine, which has to be added to the preparation. This is not practical in intact animals, and in addition, the temporal resolution of bioluminescence imaging is relatively poor (seconds-minutes). The first genetically encoded fluorescent calcium indicator (GECI) to be used to image activity in an animal was cameleon, designed by Atsushi Miyawaki, Roger Tsien and coworkers in 1997.[1] Cameleon was first used successfully in an animal by Rex Kerr, William Schafer and coworkers to record from neurons and muscle cells of the nematode C. elegans.[2] Cameleon was subsequently used to record neural activity in flies[3] and zebrafish.[4] In mammals, the first GECI to be used in vivo was GCaMP,[5] first developed by Junichi Nakai and coworkers in 2001.[6] GCaMP has undergone numerous improvements, notably by a team of scientists at the Janelia Farm Research Campus (GENIE project, HHMI), and GCaMP6[7] in particular has become widely used in neuroscience. Very recently, G protein-coupled receptors have been harnessed to generate a series of highly specific indicators for various neurotransmitters.[8] [9]

Design principles

Genetically encoded sensors are fusion proteins, consisting of a ligand binding domain (sensor) and a fluorescent protein, attached by a short linker (flexible peptide). When the sensor domain binds the correct ligand, it changes conformation. This movement is transferred to the fluorescent protein and the resulting deformation leads to a change in fluorescence. The efficiency of this process depends critically on the length of the linker region, which has to be optimized in a labor-intensive process. The fluorescent protein is often circularly permuted, i.e. new C-terminal and N-terminal ends were created. Single-wavelength sensors are easy to use for qualitative measurements, but difficult to calibrate for quantitative measurements of ligand concentration.

A second class of sensors relies on Förster resonance energy transfer (FRET) between two fluorescent proteins (FP) of different color. The shorter wavelength FP (donor) is excited with blue light from a laser or LED. If the second FP (acceptor) is very close, the energy is transferred to the acceptor, resulting in yellow or red fluorescence. When the acceptor FP moves further away, the donor emits green fluorescence. The sensor domain is typically spliced between the two FPs, resulting in a hinge-type movement upon ligand binding that changes the distance between donor and acceptor. The imaging procedure is more complex for FRET sensors, but the fluorescence ratio can be calibrated to measure the absolute concentration of a ligand. Read-out via fluorescence lifetime imaging (FLIM) of donor fluorescence is also possible, as the FRET process speeds up the fluorescence decay.

Advantages of optogenetic sensors

Drawbacks, limitations

Classes of genetically encoded indicators

Indicators have been designed to measure ion concentrations, membrane potential, neurotransmitters, and various intracellular signaling molecules. The following list provides only examples for each class; many more have been published.

Intracellular signaling

Neurotransmitters and other extracellular signals

Further reading

A recent review of GPCR-based genetically encoded fluorescent indicators for neuromodulators

External links

Notes and References

  1. Miyawaki A, Llopis J, Heim R, McCaffery JM, Adams JA, Ikura M, Tsien RY . Fluorescent indicators for Ca2+ based on green fluorescent proteins and calmodulin . Nature . 388 . 6645 . 882–887 . August 1997 . 9278050 . 10.1038/42264 . 1997Natur.388..882M . 13745050 . free .
  2. Kerr R, Lev-Ram V, Baird G, Vincent P, Tsien RY, Schafer WR . Optical imaging of calcium transients in neurons and pharyngeal muscle of C. elegans . Neuron . 26 . 3 . 583–594 . June 2000 . 10896155 . 10.1016/s0896-6273(00)81196-4 . 311998 . free .
  3. Fiala A, Spall T, Diegelmann S, Eisermann B, Sachse S, Devaud JM, Buchner E, Galizia CG . 6 . Genetically expressed cameleon in Drosophila melanogaster is used to visualize olfactory information in projection neurons . Current Biology . 12 . 21 . 1877–1884 . October 2002 . 12419190 . 10.1016/s0960-9822(02)01239-3 . 6312049 . free . 2002CBio...12.1877F .
  4. Higashijima S, Masino MA, Mandel G, Fetcho JR . Imaging neuronal activity during zebrafish behavior with a genetically encoded calcium indicator . Journal of Neurophysiology . 90 . 6 . 3986–3997 . December 2003 . 12930818 . 10.1152/jn.00576.2003 . 2230173 .
  5. Ji G, Feldman ME, Deng KY, Greene KS, Wilson J, Lee JC, Johnston RC, Rishniw M, Tallini Y, Zhang J, Wier WG, Blaustein MP, Xin HB, Nakai J, Kotlikoff MI . 6 . Ca2+-sensing transgenic mice: postsynaptic signaling in smooth muscle . The Journal of Biological Chemistry . 279 . 20 . 21461–21468 . May 2004 . 14990564 . 10.1074/jbc.M401084200 . free .
  6. Nakai J, Ohkura M, Imoto K . A high signal-to-noise Ca(2+) probe composed of a single green fluorescent protein . Nature Biotechnology . 19 . 2 . 137–141 . February 2001 . 11175727 . 10.1038/84397 . 30254550 .
  7. Chen TW, Wardill TJ, Sun Y, Pulver SR, Renninger SL, Baohan A, Schreiter ER, Kerr RA, Orger MB, Jayaraman V, Looger LL, Svoboda K, Kim DS . 6 . Ultrasensitive fluorescent proteins for imaging neuronal activity . Nature . 499 . 7458 . 295–300 . July 2013 . 23868258 . 3777791 . 10.1038/nature12354 . 2013Natur.499..295C .
  8. Ravotto L, Duffet L, Zhou X, Weber B, Patriarchi T . A Bright and Colorful Future for G-Protein Coupled Receptor Sensors . Frontiers in Cellular Neuroscience . 14 . 67 . 2020 . 32265667 . 7098945 . 10.3389/fncel.2020.00067 . free .
  9. Rohner . Valentin Lu . Lamothe-Molina . Paul J. . Patriarchi . Tommaso . 2024-01-30 . Engineering, applications, and future perspectives of GPCR -based genetically encoded fluorescent indicators for neuromodulators . Journal of Neurochemistry . 168 . 3 . 163–184 . en . 10.1111/jnc.16045 . 0022-3042. free . 38288673 . 20.500.11850/659388 . free .
  10. Jones-Tabah J, Mohammad H, Hadj-Youssef S, Kim LE, Martin RD, Benaliouad F, Tanny JC, Clarke PB, Hébert TE . 6 . Dopamine D1 receptor signalling in dyskinetic Parkinsonian rats revealed by fiber photometry using FRET-based biosensors . Scientific Reports . 10 . 1 . 14426 . September 2020 . 32879346 . 7468292 . 10.1038/s41598-020-71121-8 . 2020NatSR..1014426J .
  11. Sofroniew NJ . Q&A: The brain under a mesoscope: the forest and the trees . BMC Biology . 15 . 1 . 82 . September 2017 . 28911321 . 5598035 . 10.1186/s12915-017-0426-y . free .
  12. Pulin M, Stockhausen KE, Masseck OA, Kubitschke M, Busse B, Wiegert JS, Oertner TG . Orthogonally-polarized excitation for improved two-photon and second-harmonic-generation microscopy, applied to neurotransmitter imaging with GPCR-based sensors . EN . Biomedical Optics Express . 13 . 2 . 777–790 . February 2022 . 35284188 . 8884218 . 10.1364/BOE.448760 .
  13. Zhang Y, Rózsa M, Bushey D, Zheng J, Reep D, Broussard GJ, Tsang A, Tsegaye G, Patel R, Narayan S, Lim JX . Janelia Research Campus . 2020. jGCaMP8 Fast Genetically Encoded Calcium Indicators . 361685 . 10.25378/JANELIA.13148243.
  14. Berglund K, Schleich W, Wang H, Feng G, Hall WC, Kuner T, Augustine GJ . Imaging synaptic inhibition throughout the brain via genetically targeted Clomeleon . Brain Cell Biology . 36 . 1–4 . 101–118 . August 2008 . 18850274 . 2674236 . 10.1007/s11068-008-9031-x .
  15. Wu . Sheng-Yi . Wen . Yurong . Serre . Nelson B. C. . Laursen . Cathrine Charlotte Heiede . Dietz . Andrea Grostøl . Taylor . Brian R. . Drobizhev . Mikhail . Molina . Rosana S. . Aggarwal . Abhi . Rancic . Vladimir . Becker . Michael . Ballanyi . Klaus . Podgorski . Kaspar . Hirase . Hajime . Nedergaard . Maiken . 2022-09-06 . Dutzler . Raimund . A sensitive and specific genetically-encoded potassium ion biosensor for in vivo applications across the tree of life . PLOS Biology . en . 20 . 9 . e3001772 . 10.1371/journal.pbio.3001772 . 36067248 . 9481166 . 1545-7885 . free .
  16. Han J, Burgess K . Fluorescent indicators for intracellular pH . Chemical Reviews . 110 . 5 . 2709–2728 . May 2010 . 19831417 . 10.1021/cr900249z .
  17. Jin L, Han Z, Platisa J, Wooltorton JR, Cohen LB, Pieribone VA . Single action potentials and subthreshold electrical events imaged in neurons with a fluorescent protein voltage probe . Neuron . 75 . 5 . 779–785 . September 2012 . 22958819 . 3439164 . 10.1016/j.neuron.2012.06.040 .
  18. Granseth B, Odermatt B, Royle SJ, Lagnado L . Clathrin-mediated endocytosis is the dominant mechanism of vesicle retrieval at hippocampal synapses . Neuron . 51 . 6 . 773–786 . September 2006 . 16982422 . 10.1016/j.neuron.2006.08.029 . 921124 . free .
  19. Klarenbeek J, Goedhart J, van Batenburg A, Groenewald D, Jalink K . 2015-04-14 . Fourth-generation epac-based FRET sensors for cAMP feature exceptional brightness, photostability and dynamic range: characterization of dedicated sensors for FLIM, for ratiometry and with high affinity . PLOS ONE . 10 . 4 . e0122513 . 2015PLoSO..1022513K . 10.1371/journal.pone.0122513 . 4397040 . 25875503 . free.
  20. Yaginuma H, Okada Y . 2021-10-09 . Live cell imaging of metabolic heterogeneity by quantitative fluorescent ATP indicator protein, QUEEN-37C . bioRxiv . en . 2021.10.08.463131 . 10.1101/2021.10.08.463131 . 238585891.
  21. Lee SJ, Escobedo-Lozoya Y, Szatmari EM, Yasuda R . March 2009 . Activation of CaMKII in single dendritic spines during long-term potentiation . Nature . 458 . 7236 . 299–304 . 2009Natur.458..299L . 10.1038/nature07842 . 2719773 . 19295602.
  22. Oliveira AF, Yasuda R . 2013-01-14 . An improved Ras sensor for highly sensitive and quantitative FRET-FLIM imaging . PLOS ONE . 8 . 1 . e52874 . 2013PLoSO...852874O . 10.1371/journal.pone.0052874 . 3544822 . 23349692 . free.
  23. Marvin JS, Scholl B, Wilson DE, Podgorski K, Kazemipour A, Müller JA, Schoch S, Quiroz FJ, Rebola N, Bao H, Little JP, Tkachuk AN, Cai E, Hantman AW, Wang SS, DePiero VJ, Borghuis BG, Chapman ER, Dietrich D, DiGregorio DA, Fitzpatrick D, Looger LL . 6 . Stability, affinity, and chromatic variants of the glutamate sensor iGluSnFR . Nature Methods . 15 . 11 . 936–939 . November 2018 . 30377363 . 6394230 . 10.1038/s41592-018-0171-3 .
  24. Marvin JS, Shimoda Y, Magloire V, Leite M, Kawashima T, Jensen TP, Kolb I, Knott EL, Novak O, Podgorski K, Leidenheimer NJ, Rusakov DA, Ahrens MB, Kullmann DM, Looger LL . 6 . A genetically encoded fluorescent sensor for in vivo imaging of GABA . Nature Methods . 16 . 8 . 763–770 . August 2019 . 31308547 . 10.1038/s41592-019-0471-2 . 196812412 .
  25. Patriarchi T, Cho JR, Merten K, Howe MW, Marley A, Xiong WH, Folk RW, Broussard GJ, Liang R, Jang MJ, Zhong H, Dombeck D, von Zastrow M, Nimmerjahn A, Gradinaru V, Williams JT, Tian L . 6 . Ultrafast neuronal imaging of dopamine dynamics with designed genetically encoded sensors . Science . 360 . 6396 . eaat4422 . June 2018 . 29853555 . 6287765 . 10.1126/science.aat4422 .
  26. Labouesse MA, Cola RB, Patriarchi T . GPCR-Based Dopamine Sensors-A Detailed Guide to Inform Sensor Choice for In vivo Imaging . International Journal of Molecular Sciences . 21 . 21 . 8048 . October 2020 . 33126757 . 7672611 . 10.3390/ijms21218048 . free .
  27. Wan J, Peng W, Li X, Qian T, Song K, Zeng J, Deng F, Hao S, Feng J, Zhang P, Zhang Y, Zou J, Pan S, Shin M, Venton BJ, Zhu JJ, Jing M, Xu M, Li Y . 6 . A genetically encoded sensor for measuring serotonin dynamics . Nature Neuroscience . 24 . 5 . 746–752 . May 2021 . 33821000 . 8544647 . 10.1038/s41593-021-00823-7 .
  28. Kubitschke . Martin . Müller . Monika . Wallhorn . Lutz . Pulin . Mauro . Mittag . Manuel . Pollok . Stefan . Ziebarth . Tim . Bremshey . Svenja . Gerdey . Jill . Claussen . Kristin Carolin . Renken . Kim . Groß . Juliana . Gneiße . Pascal . Meyer . Niklas . Wiegert . J. Simon . 2022-12-06 . Next generation genetically encoded fluorescent sensors for serotonin . Nature Communications . en . 13 . 1 . 7525 . 10.1038/s41467-022-35200-w . 36473867 . 9726753 . 2022NatCo..13.7525K . 247454046 . 2041-1723.
  29. Unger . Elizabeth K. . Keller . Jacob P. . Altermatt . Michael . Liang . Ruqiang . Matsui . Aya . Dong . Chunyang . Hon . Olivia J. . Yao . Zi . Sun . Junqing . Banala . Samba . Flanigan . Meghan E. . Jaffe . David A. . Hartanto . Samantha . Carlen . Jane . Mizuno . Grace O. . 5 . December 2020 . Directed Evolution of a Selective and Sensitive Serotonin Sensor via Machine Learning . Cell . en . 183 . 7 . 1986–2002.e26 . 10.1016/j.cell.2020.11.040 . 8025677 . 33333022.
  30. Feng J, Zhang C, Lischinsky JE, Jing M, Zhou J, Wang H, Zhang Y, Dong A, Wu Z, Wu H, Chen W, Zhang P, Zou J, Hires SA, Zhu JJ, Cui G, Lin D, Du J, Li Y . 6 . A Genetically Encoded Fluorescent Sensor for Rapid and Specific In Vivo Detection of Norepinephrine . Neuron . 102 . 4 . 745–761.e8 . May 2019 . 30922875 . 6533151 . 10.1016/j.neuron.2019.02.037 .
  31. Dong A, He K, Dudok B, Farrell JS, Guan W, Liput DJ, Puhl HL, Cai R, Wang H, Duan J, Albarran E, Ding J, Lovinger DM, Li B, Soltesz I, Li Y . 6 . A fluorescent sensor for spatiotemporally resolved imaging of endocannabinoid dynamics in vivo . Nature Biotechnology . 787–798 . November 2021 . 40 . 5 . 34764491 . 10.1038/s41587-021-01074-4 . 9091059 . 244039925 .
  32. Duffet L, Kosar S, Panniello M, Viberti B, Bracey E, Zych AD, Radoux-Mergault A, Zhou X, Dernic J, Ravotto L, Tsai YC, Figueiredo M, Tyagarajan SK, Weber B, Stoeber M, Gogolla N, Schmidt MH, Adamantidis AR, Fellin T, Burdakov D, Patriarchi T . 6 . A genetically encoded sensor for in vivo imaging of orexin neuropeptides . Nature Methods . 19 . 2 . 231–241 . February 2022 . 35145320 . 8831244 . 10.1038/s41592-021-01390-2 .
  33. Nasu . Yusuke . Murphy-Royal . Ciaran . Wen . Yurong . Haidey . Jordan N. . Molina . Rosana S. . Aggarwal . Abhi . Zhang . Shuce . Kamijo . Yuki . Paquet . Marie-Eve . Podgorski . Kaspar . Drobizhev . Mikhail . Bains . Jaideep S. . Lemieux . M. Joanne . Gordon . Grant R. . Campbell . Robert E. . 2021-12-06 . A genetically encoded fluorescent biosensor for extracellular l-lactate . Nature Communications . en . 12 . 1 . 7058 . 10.1038/s41467-021-27332-2 . 34873165 . 8648760 . 2021NatCo..12.7058N . 2041-1723.
  34. Greenwald EC, Mehta S, Zhang J . Genetically Encoded Fluorescent Biosensors Illuminate the Spatiotemporal Regulation of Signaling Networks . Chemical Reviews . 118 . 24 . 11707–11794 . December 2018 . 30550275 . 7462118 . 10.1021/acs.chemrev.8b00333 .