Flicker (light) explained

In visual perception, flicker is a human-visible change in luminance of an illuminated surface or light source which can be due to fluctuations of the light source itself, or due to external causes such as due to rapid fluctuations in the voltage of the power supply (power-line flicker) or incompatibility with an external dimmer.

Twinkling, also called scintillation, is a generic term for variations in apparent brightness, colour, or position of a distant luminous object viewed through a medium.

Flicker exists for other organisms having different perceptual thresholds.

Light meters and image sensors can potentially detect flicker at much higher frequency bands than human vision. Shutter speeds used in motion photography can interact with high frequency flicker to produce visual artifacts in the captured imagery that betray flicker that would not otherwise be noted.

The spectral sensitivity of the human eye to flicker depends upon the mode of visual perception. Due to the flicker fusion threshold of foveal vision, steady vision can rarely detect flicker above 90 Hz, whereas flicker can be perceived during visual saccades up to or beyond 1 kHz.[1]

Flicker due to mechanical factors such as AC line frequency (typically 50 or 60 Hz) will have a stable frequency structure, whereas the flicker of a damp or failing light bulb will often have a chaotic or erratic frequency structure.

Temporal light modulation

Temporal light modulation (TLM) is a slightly broader concept defined by the International Commission on Illumination (CIE) as fluctuation in luminous quantity or spectral distribution of light with respect to time.[2] The effect is typically connected to lighting products such as lamps and luminaires where the light is modulated in order to provide some functionality, such as dimming or color change. TLM can cause temporal light artifacts (TLA) such as the stroboscopic effect or phantom array effect. TLM has been linked to headache and migraine, and in rare cases epileptic seizures. [3]

Effects

Various scientific committees have assessed the potential health, performance and safety-related aspects resulting from TLMs, including light flicker.[4] [5] [6] Adverse effects of flicker of include annoyance, reduced task performance, visual fatigue, headache and epileptic attack by photosensitive persons. The visibility aspects of flicker are given in a technical note of CIE; see CIE TN 006:2016. In general, undesired effects in the visual perception of a human observer induced by light intensity fluctuations are called temporal light artefacts (TLAs).

Root causes

Light emitted from lighting equipment such as luminaires and lamps may vary in strength as function of time, either intentionally or unintentionally. Intentional light variations are applied for warning, signalling (e.g. traffic-light signalling, flashing aviation light signals), entertainment (like stage lighting) with the purpose that flicker is perceived by people. Generally, the light output of lighting equipment may also have unintentional light level modulations due to the lighting equipment itself. The magnitude, shape, periodicity and frequency of the TLMs will depend on many factors such as the type of light source, the electrical mains-supply frequency, the driver or ballast technology and type of light regulation technology applied (e.g. pulse-width modulation). If the modulation frequency is below the flicker fusion threshold and if the magnitude of the TLM exceeds a certain level, then such TLMs are perceived as flicker. These TLM-properties may vary over time due to aging effects. Component failure within lighting equipment or end-of-life behavior of lighting equipment can also give rise to flicker.[7] Furthermore, external factors such as incompatibility with dimmers or presence of mains-supply voltage fluctuations (power-line flicker) are root causes of flicker.[8]

Flicker can also be perceived from naturally modulated light sources like candle light or a sunlit water surface or it may be experienced while driving along a row of trees lit by the sun. TLMs and resulting flicker can be seen also while driving with a certain speed along a street or through a tunnel lit by lighting equipment positioned with a regular spacing.[9]

Visibility

Temporal light modulations become visible if the modulation frequency is below the flicker fusion threshold and if the magnitude of the TLM exceeds a certain levels.

There are much more factors that determine the visibility of TLMs as flicker:

All observer-related influence quantities are stochastic parameters, because not all humans perceive the same light ripple in the same way. That is why perception of flicker is always expressed with a certain probability. Detailed explanations on the visibility of flicker and other temporal light artefacts are given in CIE TN 006:2016[10] and in a recorded webinar "Is it all just flicker?".[11]

Objective assessment of flicker

Light flickermeter

For objective assessment of flicker, a widely applied and IEC-standardized metric, the short-term flicker indicator (PstLM) is used. This metric is derived from the short term flicker severity metric PstV that is applied in the power quality domain for testing electrical apparatus for their potential to cause flicker via voltage fluctuations on the electrical mains network (see the IEC publications IEC 61000-3-3[12] and IEC 61000-4-15[13]). The short-term flicker indicator PstLM is implemented in a light flickermeter which processes the light measured by means of a light sensor. The light flickermeter[14] [15] consists of four processing blocks which include weighting filters to account for frequency dependency of the visibility of TLMs as well as statistical processing to enable assessing a-periodic TLMs. The specification of the light flickermeter and the test method for objective flicker assessment of lighting equipment is published in IEC technical report IEC TR 61547–1.[16]

It is recommended to calculate the value of PstLM using a light waveform recorded for at least three minutes. This enables proper assessment of flicker occurring at low repetition frequencies. NOTE - Several alternative metrics such as Modulation Depth, Flicker Percentage or Flicker Index are being applied. None of these metrics are suitable to predict actual human perception because human perception is impacted by modulation depth, modulation frequency, wave shape and if applicable the duty cycle of the TLM.

Matlab toolbox

A Matlab light flicker assessment toolbox including a function for calculating PstLM and some application examples are available[17] on the Matlab Central via the Mathworks Community.

Acceptance criterion

The perceptibility scale of PstLM (and PstV) is chosen such that a value of 1.0 corresponds to a level at which 50% of human test subjects judge the flicker to be both noticeable and irritating (Figure 1).

Test and measurement applications

The objective light flickermeter can be applied for different purposes (see Figure 2 and IEC TR 61547-1):

Publications of standards development organisations

  1. IEC TR 61457-1:2017: light flickermeter specification and verification method, and test procedure for voltage fluctuation immunity and dimmer compatibility.
  2. NEMA 77-2017:[18] among others, flicker test Methods and guidance for acceptance criteria.

Ceiling fans and wind turbines

Other examples of light flicker can sometimes be associated with ceiling fans[19] or wind turbines[20] This occurs when the rotation of the blade continuously blocks the light source (i.e. indoor ceiling light or Sun), causing visual flicker.

See also

References

  1. Web site: The scientific reason you don't like LED bulbs — and the simple way to fix them . 3 August 2021 . Wilkins . Arnold J . 27 July 2017 . theconversation.com . The Conversation.
  2. Web site: 10.25039/TN.012.2021 . CIE TN 012:2021 Guidance on the Measurement of Temporal Light Modulation of Light Sources and Lighting Systems . CIE - International Commission on Illumination. . 2021 . 3 October 2023.
  3. Book: 10.25039/TR.249.2022 . CIE 249:2022 Visual Aspects of Time-Modulated Lighting Systems . CIE - International Commission on Illumination. . 2022 . 978-3-902842-68-8.
  4. IEEE Std 1789:2015, IEEE Recommended Practices for Modulating Current in High-Brightness LEDs for Mitigating Health Risks to Viewers (link).
  5. SCENIHR (Scientific Committee on Emerging and Newly Identified Health Risks), Health effects of artificial light, 19 March 2012 .
  6. SCHEER (EC Scientific Committee on Health, Environmental and Emerging Risks), Final Opinion on potential risks to human health of Light Emitting Diodes (LEDs), June 2018.https://ec.europa.eu/health/scientific_committees/consultations/public_consultations/scheer_consultation_05_en
  7. Fluorescent lamp end-of-life flicker problems.Fluorescent lamp#Flicker problems
  8. R. Cai, Flicker interaction studies and flickermeter improvement, PhD thesis, Eindhoven : Technische Universiteit Eindhoven, 2009.https://pure.tue.nl/ws/files/3321108/200911297.pdf
  9. See flicker problems in the Queensway Tunnel.
  10. CIE TN 006:2016, Visual Aspects of Time-Modulated Lighting Systems – Definitions and Measurement Models (pdf).
  11. Web site: Sekulovski . Dragan . Signify . Apr 4, 2016 . Is it all Flicker? . bot: unknown . https://web.archive.org/web/20200903025128/https://www.youtube.com/watch?v=1gZg6eUmEGA . 3 September 2020 . YouTube . 1 March 2018 .
  12. IEC 61000-3-3 (ed. 3.1), Electromagnetic compatibility (EMC) – Part 3-3: Limits – Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection.https://webstore.iec.ch/publication/60730
  13. IEC 61000-4-15 (ed. 2), Electromagnetic compatibility (EMC) –Part 4-15: Testing and measurement techniques – Flickermeter –Functional and design specifications.https://webstore.iec.ch/publication/22269
  14. J. Drápela, J. Šlezingr, A light-flickermeter – Part I: Design, Proceedings 11th International Scientific Conference Electric Power Engineering 2010, pp. 453.https://www.researchgate.net/publication/229018628_A_Light-flickermeter-Part_I_Design
  15. Lance Frater, Light Flicker and Harmonic Modelling of Electrical Lighting, PhD thesis, University of Canterbury, Christchurch, New Zealand, 2015.https://ir.canterbury.ac.nz/handle/10092/11370
  16. IEC TR 61547-1 (ed. 3), Equipment for general lighting purposes – EMC immunity requirements – Part 1: An objective light flickermeter and voltage fluctuation immunity test method.https://webstore.iec.ch/publication/64795
  17. https://nl.mathworks.com/matlabcentral/fileexchange/63445-light-flicker-assessment-toolbox Light flicker assessment toolbox Matlab Central
  18. NEMA 77-2017: Temporal Light Artifacts: Test Methods and Guidance for Acceptance Criteria.https://www.nema.org/Standards/Pages/Temporal-Light-Artifacts-Test-Methods-and-Guidance-for-Acceptance-Criteria.aspx
  19. Kent. Michael. Cheung. Toby. Li. Jiayu. Schiavon. Stefano. 2020. Experimental evaluation of visual flicker caused by ceiling fans. Building and Environment. en. 182. 107060. 10.1016/j.buildenv.2020.107060. 2020BuEnv.18207060K . 225305290 .
  20. Harding. Graham. Harding. Parmela. Li. Arnold. Wilkins. Stefano. 2008. Wind turbines, flicker, and photosensitive epilepsy: Characterizing the flashing that may precipitate seizures and optimizing guidelines to prevent them. Epilepsia. en. 46. 6. 1095–1098. 10.1111/j.1528-1167.2008.01563.x. 18397297 . 16197834 . free.