Electric clock explained

An electric clock is a clock that is powered by electricity, as opposed to a mechanical clock which is powered by a hanging weight or a mainspring. The term is often applied to the electrically powered mechanical clocks that were used before quartz clocks were introduced in the 1980s. The first experimental electric clocks were constructed around the 1840s, but they were not widely manufactured until mains electric power became available in the 1890s. In the 1930s, the synchronous electric clock replaced mechanical clocks as the most widely used type of clock.

Types

Electric clocks can operate by several different types of mechanism:

History

In 1814, Sir Francis Ronalds of London invented the first electric clock.[3] It was powered with dry piles, a high voltage battery with extremely long life but the disadvantage of its electrical properties varying with the weather.[4] He trialled various means of regulating the electricity and these models proved to be reliable across a range of meteorological conditions.[5]

In 1815, Giuseppe Zamboni of Verona invented and showed another electrostatic clock run with dry pile batteries and an oscillating orb. His team produced improved clocks over many years, which were later denoted as "the most elegant and at the same time the most simple movement yet produced by the electric column".[6] Zamboni's clock had a vertical needle supported by a pivot and was so energy efficient that it could operate on one battery for over 50 years.

In 1840, Alexander Bain, a Scottish clock and instrument maker was the first to invent and patent a clock powered by electric current. His original electric clock patent is dated October 10, 1840. On January 11, 1841, Alexander Bain along with John Barwise, a chronometer maker, took out another important patent describing a clock in which an electromagnetic pendulum and an electric current is employed to keep the clock going instead of springs or weights. Later patents expanded on his original ideas.

Numerous people were intent on inventing the electric clock with electromechanical and electromagnetic designs around the year 1840, such as Wheatstone, Steinheil, Hipp, Breguet, and Garnier, both in Europe and America.

Matthäus Hipp, clockmaker born in Germany, is credited with establishing the production series, mass marketable electric clock. Hipp opened a workshop in Reutlingen, where he developed an electric clock to have the Hipp-Toggle, presented in Berlin at an exhibition in 1843. The Hipp-Toggle is a device attached to a pendulum or balance wheel that electro-mechanically allows occasional impulse or drive to the pendulum or wheel as its amplitude of swing drops below a certain level, and is so efficient that it was subsequently used in electric clocks for over a hundred years. Hipp also invented a small motor and built the chronoscope and the registering chronograph for time measurement.

The first electric clocks had prominent pendulums because this was a familiar shape and design. Smaller clocks and watches with a spiral-balance are made on the same principles as pendulum clocks.

In 1918, Henry Ellis Warren invented the first synchronous electric clock in Ashland, MA, which kept time from the oscillations of the power grid.[7] [8] In 1931, the Synclock was the first commercial synchronous electric clock sold in the UK.[8]

Electromechanical clock

A clock that employs electricity in some form to power a conventional clock mechanism is an electromechanical clock. Any spring or weight driven clock that uses electricity (either AC or DC) to rewind the spring or raise the weight of a mechanical clock then is an electromechanical clock. In electromechanical clocks the electricity serves no time keeping function. The timekeeping function is regulated by the pendulum. Near the end of the nineteenth century, the availability of the dry cell battery made it practical to use electric power in clocks. The use of electricity then led to many variations of clock and motor designs. Electromechanical clocks were made as individual timepieces but most commonly were used as integral parts of synchronized time installations. Experience in telegraphy led to connecting remote clocks (slave clocks) via wires to a controlling (master clock) clock. The goal was to create a clock system where each clock displayed exactly the same time. The master and the slaves are electromechanical clocks. The master clock has a conventional self-winding clock mechanism that is rewound electrically. The slave clock mechanism is not a conventional clock mechanism as it consists only of a ratchet wheel and time train. Slave clocks rely upon electrical impulses from the master clock to mechanically move the clock hands one unit of time. Synchronized time systems are made up of one master clock and any number of slave clocks. The slave clocks are connected by wires to the master clock. These systems are found in locations where multiple clocks would be used such as learning institutions, businesses, factories, transportation networks, banks, offices and government facilities. A notable example of this type of system is the Shortt-Synchronome clock, which is an example of an electromechanical gravity remontoire. These self-winding clock systems were usually low voltage DC. They were installed through the 1950s and by then systems with synchronous motor clocks were becoming the clock system of choice.

Electromagnetic clock

The configuration of this device is comparatively very simple and reliable. The electric current powers either a pendulum or an electromechanical oscillator.

The electromechanical oscillator component has an attached magnet that passes two inductors. When the magnet passes the first inductor or sensor, the simple amplifier causes the current through the second inductor, and the second inductor works as an electromagnet, providing an energy pulse to the moving oscillator. This oscillator is responsible for the accuracy of the clock. The electronic part would not generate electrical pulses if the oscillator was absent or did not move. The resonant frequency of the mechanical oscillator should be several times per second.

Synchronous electric clock

A synchronous electric clock does not contain a timekeeping oscillator such as a pendulum or balance wheel, but instead counts the oscillations of the AC utility current from its wall plug to keep time. It consists of a small AC synchronous motor, which turns the clock's hands through a reduction gear train.[9] The motor contains electromagnets which create a rotating magnetic field which turns an iron rotor. The rotation rate of the motor shaft is synchronized to the utility frequency; 60 cycles per second (Hz) in North America and parts of South America, 50 cycles per second in most other countries. The gear train scales this rotation so the minute hand rotates once per hour. Thus the synchronous clock can be regarded as not so much a timekeeper as a mechanical counter, whose hands display a running count of the number of cycles of alternating current.

One of the gears turning the clock's hands has a shaft with a sliding friction fitting, so the clock's hands can be turned manually by a knob on the back or on the bottom, to set the clock.

Synchronous motor clocks are rugged because they do not have a delicate pendulum or balance wheel. However, a temporary power outage will stop the clock, which will show the wrong time when power is restored. Some synchronous clocks (e.g. Telechron) have an indicator which shows if it has stopped and restarted.

Number of poles

Some electric clocks have a simple two-pole synchronous motor which runs at one revolution per cycle of power, i.e., 3600 RPM at 60 Hz and 3000 RPM at 50 Hz.[10] However most electric clocks have rotors with more magnetic poles (teeth), consequently rotating at a smaller submultiple of line frequency. This allows the gear train which turns the hands to be built with fewer gears, saving money.[11]

Accuracy

The accuracy of synchronous clocks depends on how close electric utilities keep the frequency of their current to the nominal value of 50 or 60 hertz. Although utility load variations cause frequency fluctuations which may result in errors of a few seconds during the course of a day, utilities periodically adjust the frequency of their current using UTC atomic clock time so that the total number of cycles in a day gives an average frequency that is exactly the nominal value, so synchronous clocks do not accumulate error.[12] For example, European utilities control the frequency of their grid once a day to make the total number of cycles in 24 hours correct.[13] U.S. utilities correct their frequency once the cumulative error has reached 3–10 sec. This correction is known as the Time Error Correction (TEC).

In 2011, the North American Electric Reliability Corporation (NERC),[14] a consensus-based industry organization, petitioned the Federal Energy Regulatory Commission (FERC)[15] to eliminate the TEC. While this would have freed the power companies from the threat of fines and also provided an extremely modest increase in frequency stability, it was also noted that synchronous clocks, which include wall clocks, alarm clocks, and other clocks computing the time on the basis of their electrical power, would accumulate several minutes of error between the semi-annual resets for Daylight Saving Time.[16] This consequence was reported in the American news media,[17] and the initiative was dropped. However, in late 2016 a similar proposal was again filed by the NERC to the FERC, which was approved two months later.[12] It is contingent upon the removal of the standard WEQ-006, and the NERC also petitioned the North American Energy Standard Board (NAESB),[18] a non-governmental organization that is business-oriented, for removing that standard. If the FERC adopts the NAESB petition, TECs will no longer be utilized in the United States and Canada, and clocks timed by them will likely wander uncontrolled until manually reset, however as of 2021 WEQ-006 was still in place.[19] It was noted in a technical paper by employees of the National Institute of Standards and Technology and the U.S. Naval Observatory that, had TECs not been inserted in 2016, there would have been over seven minutes lost by electrically timed clocks over much of the United States and Canada, as shown in Figure 8 of their paper.[12]

Spin-start clocks

The earliest synchronous clocks from the 1930s were not self-starting, and had to be started by spinning a starter knob on the back. A flaw in the design of these spin-start clocks was that the motor could be started in either direction, so if the starter knob was spun the wrong way the clock would run backwards, the hands turning counterclockwise. Later manual-start clocks had ratchets or other linkages which prevented backwards starting. The invention of the shaded-pole motor allowed self-starting clocks to be made, but since the clock would then restart after a power outage, the clock would give incorrect time instead of being stopped at the time of power interruption.

See also

References

Notes and References

  1. Web site: Build a Synchronous Clock. Rod. Elliott. Elliott Sound. 2016-12-13. 2018-07-11. https://web.archive.org/web/20180711170318/http://sound.whsites.net/clocks/sync.html. dead.
  2. http://www.brimarc.com/products/Quartz-Clock-Movements-23072.htm Brimarc, typical quartz clock movement specified accurate to within ±30 seconds/month
  3. Aked. C.K.. 1973. The First Electric Clock. Antiquarian Horology.
  4. Book: Ronalds, B.F.. Sir Francis Ronalds: Father of the Electric Telegraph. Imperial College Press. 2016. 978-1-78326-917-4. London.
  5. Ronalds. B.F.. Jun 2015. Remembering the First Battery-Operated Clock. Antiquarian Horology. 8 Apr 2016.
  6. Perpetual Electromotive
  7. https://patents.google.com/patent/US1283434 U.S. patent #1283434
  8. Web site: Famous Names in Electrical Horology . Electrical Horology Group . Antiquarian Horological Society, London, UK . 2011 . 2011-12-16 . https://web.archive.org/web/20120507173552/http://www.ahsoc.demon.co.uk/ehg/electricalindex.html . 2012-05-07 . dead .
  9. Book: Wise , S. J. . Electric Clocks, 2nd Ed. . Heywood & Co. . 1952 . London . 95–100 . https://web.archive.org/web/20140223035538/http://www.electricclockarchive.org/portals/0/publisheddocuments/Books/Wise%20S.J.,%20Electric%20Clocks,%20second%20edition%201952.pdf . dead . February 23, 2014 .
  10. https://web.archive.org/web/20140223035538/http://www.electricclockarchive.org/portals/0/publisheddocuments/Books/Wise%20S.J.,%20Electric%20Clocks,%20second%20edition%201952.pdf Wise (1952) Electric Clocks
  11. The speed of a synchronous motor v in revolutions per minute (RPM) is related to the number of poles by:

    v=

    120f
    p

    where f is the line frequency (50/60 Hz) and p is the number of poles on the rotor. Many designs have 30 poles, so that the motor runs at 240 RPM (at 60 Hz) or 200 RPM (at 50 Hz).
  12. https://web.archive.org/web/20171020033351/http://tf.boulder.nist.gov/general/pdf/2895.pdf NIST Paper
  13. Web site: Frequency response - National Grid. www2.nationalgrid.com. 2016-06-03. 2017-11-03. https://web.archive.org/web/20171103071509/http://www2.nationalgrid.com/uk/services/balancing-services/frequency-response/. dead.
  14. Web site: NERC. www.nerc.com.
  15. Web site: Federal Energy Regulatory Commission. www.ferc.gov.
  16. http://www.gps.gov/cgsic/meetings/2011/matsakis.pdf
  17. Web site: Appliance disruptions feared in power grid test. . 27 June 2011 .
  18. Web site: North American Energy Standards Board. www.naesb.org.
  19. Web site: NAESB Wholesale Electric Quadrant (WEQ) Update. 2022-01-07. 2022-12-06. https://web.archive.org/web/20221206104825/https://www.wecc.org/Administrative/08_Steigerwald_NAESB%20WEQ%20Update%20@%20ISAS_June%202021.pdf. dead.