TORRO scale explained

The TORRO tornado intensity scale (or T-Scale) is a scale measuring tornado intensity between T0 and T11. It was proposed by Terence Meaden of the Tornado and Storm Research Organisation (TORRO), a meteorological organisation in the United Kingdom, as an extension of the Beaufort scale.

History and derivation from Beaufort scale

The scale was tested from 1972 to 1975 and was made public at a meeting of the Royal Meteorological Society in 1975. The scale sets T0 as the equivalent of 8 on the Beaufort scale and is related to the Beaufort scale (B), up to 12 on the Beaufort scale, by the formula:

B = 2 (T + 4)

and conversely:

T = B/2 - 4

Beaufort scaleB 81012121212121212121212
TORRO scaleT 0 1234567891011

The Beaufort scale was first introduced in 1805, and in 1921 quantified. It expresses the wind speed as faster than v in the formula:

v = 0.837 B3/2 m/s

TORRO scale formula

Most UK tornadoes are T6 or below with the strongest known UK tornado estimated as a T8 (the London tornado of 1091). For comparison, the strongest detected winds in a United States tornado (during the 1999 Oklahoma tornado outbreak) would be T11 using the following formulas:

v = 2.365 (T+4)3/2 m/s

v = 8.511 (T+4)3/2 km/h

v = 5.289 (T+4)3/2 mph

v = 4.596 (T+4)3/2 kn

where v is wind speed and T is TORRO intensity number. Wind speed is defined as a 3-second gust at 10 m AGL.

Alternatively, the T-Scale formula may be expressed as:

v = 0.837 (2T+8)3/2 m/sor

v = 0.837(23/2) (T+4)3/2 m/s

or

T=(v/2.365)2/3-4

Rating process and comparisons to Fujita scale

TORRO claims it differs from the Fujita scale in that it is "purely" a wind speed scale, whereas the Fujita scale relies on damage for classification, but in practice, damage is utilised almost exclusively in both systems to infer intensity. That is because such a proxy for intensity is usually all that is available, although users of both scales would prefer direct, objective, quantitative measurements. The scale is primarily used in the United Kingdom whereas the Fujita scale has been the primary scale used in North America, continental Europe, and the rest of the world.

At the 2004 European Conference on Severe Storms, Dr. Meaden proposed a unification of the TORRO and Fujita scales as the Tornado Force or TF Scale.[1] In 2007 in the United States, the Enhanced Fujita Scale replaced the original Fujita Scale from 1971.[2] It made substantial improvements in standardizing damage descriptors through expanding and refining damage indicators and associated degrees of damage, as well as calibrated tornado wind speeds to better match the associated damage.[3] However, the EF Scale, having been designed based on construction practices in the United States, is not necessarily applicable across all regions.[4] [5] The EF-scale and variants thereof are officially used by the United States, Canada,[6] [7] France,[8] and Japan,[9] as well as unofficially in other countries, such as China.[10]

Unlike with the F scale, no analyses have been undertaken at all to establish the veracity and accuracy of the T scale damage descriptors. The scale was written in the early 1970s, and does not take into account changes such as the growth in weight of vehicles or the great reduction in numbers and change of type of railway locomotives, and was written in an environment where tornadoes of F2 or stronger are extremely rare, so little or no first-hand investigation of actual damage at the upper end of the scale was possible. The TORRO scale has more graduations than the F scale which makes it arguably more useful for tornadoes on the lower end of the scale; however, such accuracy and precision are not typically attainable in practice. Brooks and Doswell stated that "the problems associated with damage surveys and uncertainties associated with estimating wind speed from observed damage make highly precise assignments dubious".[11] In survey reports, Fujita ratings sometimes also have extra qualifications added ("minimal F2" or "upper-end F3 damage"), made by investigators who have experience of many similar tornadoes and relating to the fact that the F scale is a damage scale, not a wind speed scale.

Tornadoes are rated after they have passed and have been examined, not whilst in progress. In rating the intensity of a tornado, both direct measurements and inferences from empirical observations of the effects of a tornado are used. Few anemometers are struck by a tornado, and even fewer survive, so there are very few in-situ measurements. Therefore, almost all ratings are obtained from remote sensing techniques or as proxies from damage surveys. Weather radar is used when available, and sometimes photogrammetry or videogrammetry estimates wind speed by measuring tracers in the vortex. In most cases, aerial and ground damage surveys of structures and vegetation are utilised, sometimes with engineering analysis. Also sometimes available are ground swirl patterns (cycloidal marks) left in the wake of a tornado. If an on site analysis is not possible, either for retrospective ratings or when personnel cannot reach a site, photographs, videos, or descriptions of damage may be utilised.

TORRO scale parameters

The 12 categories for the TORRO scale are listed below, in order of increasing intensity. Although the wind speeds and photographic damage examples are updated, which are more or less still accurate. However, for the actual TORRO scale in practice, damage indicators (the type of structure which has been damaged) are predominantly used in determining the tornado intensity.

ScaleWind speed
(Estimated)
Potential damageExample of damage
mphkm/hm/s
T039 - 54 61 - 86 17 - 24Light damage.Loose light litter raised from ground level in spirals. Tents, and marquees seriously disturbed; most exposed tiles slates on roofs dislodged. Twigs snapped; trail visible through crops. Paper and leaves lifted off the ground.
T155 - 72 87 - 115 25 - 32Mild damage.Deckchairs, small plants, heavy litter becomes airborne; minor damage to sheds. More serious dislodging of tiles, slates, chimney pots. Wooden fences flattened. Slight damage to hedges and trees.
T273 - 92 116 - 147 33 - 41Moderate damage.Heavy mobile homes displaced, light caravans blown over, garden sheds destroyed, garage roofs torn away, much damage to tiled roofs and chimney stacks. General damage to trees, some big branches twisted or snapped off, small trees uprooted.
T393 - 114 148 - 184 42 - 51Strong damage.Mobile homes overturned / badly damaged; light caravans destroyed; garages and weak outbuildings destroyed; house roof timbers considerably exposed. Some of the bigger trees snapped or uprooted.
T4115 - 136 185 - 220 52 - 61Severe damage.Motor cars levitated. Mobile homes airborne / destroyed; sheds airborne for considerable distances; entire roofs removed from some houses; roof timbers of stronger brick or stone houses completely exposed; gable ends torn away. Numerous trees uprooted or snapped.
T5137 - 160 221 - 259 62 - 72Intense damage.Heavy motor vehicles levitated; more serious building damage than for T4, yet house walls usually remaining; the oldest, weakest buildings may collapse completely. (e.g. 2005 Birmingham tornado)
T6161 - 186 260 - 299 73 - 83Moderately - devastating damage.Strongly built houses lose entire roofs and perhaps also a wall; windows broken on skyscrapers, more of the less-strong buildings collapse. (e.g. 1913 United Kingdom tornado outbreak)
T7187 - 212 300 - 342 84 - 95Strongly - devastating damage.Wooden-frame houses wholly demolished; some walls of stone or brick houses beaten down or collapse; skyscrapers twisted; steel-framed warehouse-type constructions may buckle slightly. Locomotives thrown over. Noticeable debarking of trees by flying debris. (e.g. 2008 Poland tornado outbreak)
T8213 - 240 343 - 385 96 - 107Severely - devastating damage.Motor cars hurled great distances. Wooden-framed houses and their contents dispersed over long distances; stone or brick houses irreparably damaged; skyscrapers badly twisted and may show a visible lean to one side; shallowly anchored high rises may be toppled; other steel-framed buildings buckled. (e.g. 2021 South Moravia tornado)
T9241 - 269 386 - 432 108 - 120Intensely - devastating damage.Many steel-framed buildings badly damaged; skyscrapers toppled; locomotives or trains hurled some distances. Complete debarking of any standing tree-trunks. (e.g. 1984 Ivanovo tornado)
T10270 - 299 433 - 482 121 - 134Super damage.Entire frame houses and similar buildings lifted bodily or completely from foundations and carried a large distance to disintegrate. Steel-reinforced concrete buildings may be severely damaged or almost obliterated. (e.g. 1930 Montello tornado)
T11>300 >483 >135Phenomenal damage.Strong framed, well built houses leveled off foundations and swept away. Mansions are completely swept, only their flooring or foundations remain, with no trace of debris. Steel-reinforced concrete structures are completely destroyed. Tall buildings collapse. Some cars, trucks and train cars can be thrown approximately 1 mile (1.6 kilometres). (e.g. 1764 Woldegk tornado)
T0 T1 T2 T3 T4 T5 T6 T7 T8 T9 T10 T11
Weak StrongViolent

See also

References

External links

Notes and References

  1. Web site: Meaden . Terence . TORRO members . Tornado Force or TF Scale . Tornado and Storm Research Organisation . 2004 . dead . https://web.archive.org/web/20100430211910/http://www.torro.org.uk/TORRO/ECSS_Slide_Show/2004%20SPAIN%20ECSS%20Post-FINAL%20slide%20show.html . 2010-04-30 .
  2. Web site: Grazulis . Tom . Thomas P. Grazulis . The Fujita Scale of Tornado Intensity . The Tornado Project . 1999 . 2011-12-31 . dead . https://web.archive.org/web/20111230005516/http://www.tornadoproject.com/fscale/fscale.htm . 2011-12-30 .
  3. Web site: Godfrey . Elaine . The Enhanced Fujita Tornado Scale . National Climatic Data Center . 2008 . 2011-12-31 .
  4. IF Scale Steering Group . The International Fujita (IF) Scale: Tornado and Wind Damage Assessment Guide . European Severe Storms Laboratory.
  5. Nucuta . C. . Timis . C. . Butiu . C. . Scridonesi . O. . 2011 . Assessment of Tornados with the Enhanced Fujita Scale in Romania . Babes Bolyai University Faculty of Geography . English . 568–575. .
  6. Web site: Enhanced Fujita Scale (EF-Scale). 10 May 2013 . Environment Canada. 19 April 2014.
  7. http://www.theweathernetwork.com/news/storm_watch_stories3&stormfile=Measuring_tornadoes__F_vs._EF_scales_03_04_2012/ Measuring tornadoes: F-scale vs. EF-scale
  8. Web site: KERAUNOS . Intensité des tornades : l'échelle de Fujita améliorée .
  9. Suzuki . Shota . Tanaka . Yoshinobu . The Japanese Enhanced Fujita Scale: Its Development and Implementation . Japan Meteorological Agency.
  10. Chen . Jiayi . Cai . Xuhui . Wang . Hongyu . Kang . Ling . Zhang . Hongshen . Song . Yu . Zhu . Hao . Zheng . Wei . Li . Fengju . April 2018 . Tornado climatology of China . International Journal of Climatology . en . 38 . 5 . 2478–2489 . 10.1002/joc.5369 . 2018IJCli..38.2478C . 0899-8418.
  11. Brooks . Harold . Harold E. Brooks . Charles A. Doswell III . Some aspects of the international climatology of tornadoes by damage classification . Atmospheric Research . 56 . 1–4 . 191–201 . 2001 . 10.1016/S0169-8095(00)00098-3 . 2001AtmRe..56..191B .