Choked flow is a compressible flow effect. The parameter that becomes "choked" or "limited" is the fluid velocity.
Choked flow is a fluid dynamic condition associated with the Venturi effect. When a flowing fluid at a given pressure and temperature passes through a constriction (such as the throat of a convergent-divergent nozzle or a valve in a pipe) into a lower pressure environment the fluid velocity increases. At initially subsonic upstream conditions, the conservation of energy principle requires the fluid velocity to increase as it flows through the smaller cross-sectional area of the constriction. At the same time, the venturi effect causes the static pressure, and therefore the density, to decrease at the constriction. Choked flow is a limiting condition where the mass flow cannot increase with a further decrease in the downstream pressure environment for a fixed upstream pressure and temperature.
For homogeneous fluids, the physical point at which the choking occurs for adiabatic conditions is when the exit plane velocity is at sonic conditions; i.e., at a Mach number of 1.[1] [2] [3] At choked flow, the mass flow rate can be increased only by increasing the upstream density of the substance.
The choked flow of gases is useful in many engineering applications because the mass flow rate is independent of the downstream pressure, and depends only on the temperature and pressure and hence the density of the gas on the upstream side of the restriction. Under choked conditions, valves and calibrated orifice plates can be used to produce a desired mass flow rate.
If the fluid is a liquid, a different type of limiting condition (also known as choked flow) occurs when the venturi effect acting on the liquid flow through the restriction causes a decrease of the liquid pressure beyond the restriction to below that of the liquid's vapor pressure at the prevailing liquid temperature. At that point, the liquid partially flashes into bubbles of vapor and the subsequent collapse of the bubbles causes cavitation. Cavitation is quite noisy and can be sufficiently violent to physically damage valves, pipes and associated equipment. In effect, the vapor bubble formation in the restriction prevents the flow from increasing any further.[4] [5]
All gases flow from higher pressure to lower pressure. Choked flow can occur at the change of the cross section in a de Laval nozzle or through an orifice plate. The choked velocity is observed upstream of an orifice or nozzle. The upstream volumetric flow rate is lower than the downstream condition because of the higher upstream density. The choked velocity is a function of the upstream pressure but not the downstream. Although the velocity is constant, the mass flow rate is dependent on the density of the upstream gas, which is a function of the upstream pressure. Flow velocity reaches the speed of sound in the orifice, and it may be termed a .
Assuming ideal gas behavior, steady-state choked flow occurs when the downstream pressure falls below a critical value
p*
p* | |
p0 |
=\left(
2 | |
\gamma+1 |
| ||||
\right) |
\gamma
cp/cv
p0
For air with a heat capacity ratio
\gamma=1.4
p*=0.528p0
\gamma
0.487<
*/p | |
p | |
0 |
<0.587
When the gas velocity is choked, one can obtain the mass flowrate as a function of the upstream pressure. For isentropic flow Bernoulli's equation should hold:
h+
v2 | |
2 |
=
CPT | |
\mu |
+
v2 | |
2 |
=const
where
h
CP=
\gamma | |
\gamma-1 |
R
R
T
vmax=\sqrt{
2 | |
\mu |
CPT}
In a choked flow this velocity happens to coincide exactly with the sonic velocity
* | |
c | |
s |
* | |
c | |
s |
=\sqrt{\gamma
p | |
\rho* |
where
\rho*
p
p=
| |||||||||||||
2}{\gamma} |
=
| |||
A* |
| |||||||
\gamma |
taking in account that
\rho*
* | |
c | |
s |
A*=
m |
P0 ≈ p
A* ≈ A
m |
=\gammaP0A\left(
2 | |
\mu |
CPT
-1/2 | |
0\right) |
as an approximate equation for the mass flowrate.
The more precise equation for the choked mass flow rate is:
m |
=CdA\sqrt{\gamma\rho0P0\left(
2 | |
\gamma+1 |
| ||||
\right) |
Where: | ||||
| mass flow rate, in kg/s | |||
---|---|---|---|---|
Cd | discharge coefficient, dimensionless | |||
A | discharge hole cross-sectional area, in m² | |||
\gamma |
| |||
cp | specific heat of the gas at constant pressure | |||
cv | specific heat of the gas at constant volume | |||
\rho0 | real gas (total) density at total pressure P0 T0 | |||
P0 | absolute upstream total pressure of the gas, in Pa, or kg/m·s² | |||
T0 | absolute upstream total temperature of the gas, in K |
The mass flow rate is primarily dependent on the cross-sectional area
A
P
T
The value of
Cd
Cd=
| |||
A\sqrt{2\rho\DeltaP |
Where: | |||
Cd | discharge coefficient through the constriction (dimensionless) | ||
---|---|---|---|
A | cross-sectional area of flow constriction (unit length squared) | ||
| mass flow rate of fluid through constriction (unit mass of fluid per unit time) | ||
\rho | density of fluid (unit mass per unit volume) | ||
\DeltaP | pressure drop across constriction (unit force per unit area) |
The above equations calculate the steady state mass flow rate for the pressure and temperature existing in the upstream pressure source.
If the gas is being released from a closed high-pressure vessel, the above steady state equations may be used to approximate the initial mass flow rate. Subsequently, the mass flow rate decreases during the discharge as the source vessel empties and the pressure in the vessel decreases. Calculating the flow rate versus time since the initiation of the discharge is much more complicated, but more accurate.
The technical literature can be confusing because many authors fail to explain whether they are using the universal gas law constant R, which applies to any ideal gas or whether they are using the gas law constant Rs, which only applies to a specific individual gas. The relationship between the two constants is Rs = R / M where M is the molecular weight of the gas.
If the upstream conditions are such that the gas cannot be treated as ideal, there is no closed form equation for evaluating the choked mass flow. Instead, the gas expansion should be calculated by reference to real gas property tables, where the expansion takes place at constant enthalpy.
The minimum pressure ratios required for choked conditions to occur (when some typical industrial gases are flowing) are presented in Table 1. The ratios were obtained using the criterion that choked flow occurs when the ratio of the absolute upstream pressure to the absolute downstream pressure is equal to or greater than
([\gamma+1]/2)\gamma/(\gamma
\gamma
Gas | \gamma=
| Pu/Pd for choked flow | |||
---|---|---|---|---|---|
Dry air | 1.400 at 20 °C | 1.893 | |||
Nitrogen | 1.404 at 15 °C | 1.895 | |||
Oxygen | 1.400 at 20 °C | 1.893 | |||
Helium | 1.660 at 20 °C | 2.049 | |||
Hydrogen | 1.410 at 20 °C | 1.899 | |||
Methane | 1.307 | 1.837 | |||
Propane | 1.131 | 1.729 | |||
Butane | 1.096 | 1.708 | |||
Ammonia | 1.310 at 15 °C | 1.838 | |||
Chlorine | 1.355 | 1.866 | |||
Sulfur dioxide | 1.290 at 15 °C | 1.826 | |||
Carbon monoxide | 1.404 | 1.895 | |||
Carbon dioxide | 1.30 | 1.83 |
Notes:
The flow through a venturi nozzle achieves a much lower nozzle pressure than downstream pressure. Therefore, the pressure ratio is the comparison between the upstream and nozzle pressure. Therefore, flow through a venturi can reach Mach 1 with a much lower upstream to downstream ratio.[9]
The flow of real gases through thin-plate orifices never becomes fully choked. The mass flow rate through the orifice continues to increase as the downstream pressure is lowered to a perfect vacuum, though the mass flow rate increases slowly as the downstream pressure is reduced below the critical pressure.[10] Cunningham (1951) first drew attention to the fact that choked flow does not occur across a standard, thin, square-edged orifice.[11] [12]
In the case of upstream air pressure at atmospheric pressure and vacuum conditions downstream of an orifice, both the air velocity and the mass flow rate become choked or limited when sonic velocity is reached through the orifice.
Figure 1a shows the flow through the nozzle when it is completely subsonic (i.e. the nozzle is not choked). The flow in the chamber accelerates as it converges toward the throat, where it reaches its maximum (subsonic) speed at the throat. The flow then decelerates through the diverging section and exhausts into the ambient as a subsonic jet. In this state, lowering the back pressure increases the flow speed everywhere in the nozzle.[13]
When the back pressure, pb, is lowered enough, the flow speed is Mach 1 at the throat, as in figure 1b. The flow pattern is exactly the same as in subsonic flow, except that the flow speed at the throat has just reached Mach 1. Flow through the nozzle is now choked since further reductions in the back pressure can't move the point of M=1 away from the throat. However, the flow pattern in the diverging section does change as you lower the back pressure further.[13]
As pb is lowered below that needed to just choke the flow, a region of supersonic flow forms just downstream of the throat. Unlike in subsonic flow, the supersonic flow accelerates as it moves away from the throat. This region of supersonic acceleration is terminated by a normal shock wave. The shock wave produces a near-instantaneous deceleration of the flow to subsonic speed. This subsonic flow then decelerates through the remainder of the diverging section and exhausts as a subsonic jet. In this regime if you lower or raise the back pressure you move the shock wave away from (increase the length of supersonic flow in the diverging section before the shock wave) the throat.[13]
If the pb is lowered enough, the shock wave sits at the nozzle exit (figure 1d). Due to the long region of acceleration (the entire nozzle length) the flow speed reaches its maximum just before the shock front. However, after the shock the flow in the jet is subsonic.[13]
Lowering the back pressure further causes the shock to bend out into the jet (figure 1e), and a complex pattern of shocks and reflections is set up in the jet that create a mixture of subsonic and supersonic flow, or (if the back pressure is low enough) just supersonic flow. Because the shock is no longer perpendicular to the flow near the nozzle walls, it deflects the flow inward as it leaves the exit producing an initially contracting jet. This is referred as overexpanded flow because in this case the pressure at the nozzle exit is lower than that in the ambient (the back pressure)- i.e. the flow has been expanded by the nozzle too much.[13]
A further lowering of the back pressure changes and weakens the wave pattern in the jet. Eventually the back pressure becomes low enough so that it is now equal to the pressure at the nozzle exit. In this case, the waves in the jet disappear altogether (figure 1f), and the jet becomes uniformly supersonic. This situation, since it is often desirable, is referred to as the 'design condition'.[13]
Finally, lowering the back-pressure even further creates a new imbalance between the exit and back pressures (exit pressure greater than back pressure), figure 1g. In this situation (called 'underexpanded') expansion waves (that produce gradual turning perpendicular to the axial flow and acceleration in the jet) form at the nozzle exit, initially turning the flow at the jet edges outward in a plume and setting up a different type of complex wave pattern.[13]