The Seebeck coefficient (also known as thermopower,[1] thermoelectric power, and thermoelectric sensitivity) of a material is a measure of the magnitude of an induced thermoelectric voltage in response to a temperature difference across that material, as induced by the Seebeck effect.[2] The SI unit of the Seebeck coefficient is volts per kelvin (V/K),[2] although it is more often given in microvolts per kelvin (μV/K).
The use of materials with a high Seebeck coefficient[3] is one of many important factors for the efficient behaviour of thermoelectric generators and thermoelectric coolers. More information about high-performance thermoelectric materials can be found in the Thermoelectric materials article. In thermocouples the Seebeck effect is used to measure temperatures, and for accuracy it is desirable to use materials with a Seebeck coefficient that is stable over time.
Physically, the magnitude and sign of the Seebeck coefficient can be approximately understood as being given by the entropy per unit charge carried by electrical currents in the material. It may be positive or negative. In conductors that can be understood in terms of independently moving, nearly-free charge carriers, the Seebeck coefficient is negative for negatively charged carriers (such as electrons), and positive for positively charged carriers (such as electron holes).
One way to define the Seebeck coefficient is the voltage built up when a small temperature gradient is applied to a material, and when the material has come to a steady state where the current density is zero everywhere. If the temperature difference ΔT between the two ends of a material is small, then the Seebeck coefficient of a material is defined as:
S=-{\DeltaV\over\DeltaT}
Note that the voltage shift expressed by the Seebeck effect cannot be measured directly, since the measured voltage (by attaching a voltmeter) contains an additional voltage contribution, due to the temperature gradient and Seebeck effect in the measurement leads. The voltmeter voltage is always dependent on relative Seebeck coefficients among the various materials involved.
Most generally and technically, the Seebeck coefficient is defined in terms of the portion of electric current driven by temperature gradients, as in the vector differential equation
J=-\sigma\boldsymbol\nablaV-\sigmaS\boldsymbol\nablaT
\scriptstyleJ
\scriptstyle\sigma
\scriptstyle\boldsymbol\nablaV
\scriptstyle\boldsymbol\nablaT
\scriptstyleJ=0
\boldsymbol\nablaV=-S\boldsymbol\nablaT.
The sign is made explicit in the following expression:
S=-
V\rm-V\rm | |
T\rm-T\rm |
The Seebeck effect is generally dominated by the contribution from charge carrier diffusion (see below) which tends to push charge carriers towards the cold side of the material until a compensating voltage has built up. As a result, in p-type semiconductors (which have only positive mobile charges, electron holes), S is positive. Likewise, in n-type semiconductors (which have only negative mobile charges, electrons), S is negative. In most conductors, however, the charge carriers exhibit both hole-like and electron-like behaviour and the sign of S usually depends on which of them predominates.
\scriptstyle\Pi
S=
\Pi | |
T |
,
T
\scriptstylelK
S=\int
lK | |
T |
dT.
\scriptstyleS=0
See also: Thermocouple. In practice the absolute Seebeck coefficient is difficult to measure directly, since the voltage output of a thermoelectric circuit, as measured by a voltmeter, only depends on differences of Seebeck coefficients. This is because electrodes attached to a voltmeter must be placed onto the material in order to measure the thermoelectric voltage. The temperature gradient then also typically induces a thermoelectric voltage across one leg of the measurement electrodes. Therefore, the measured Seebeck coefficient is a contribution from the Seebeck coefficient of the material of interest and the material of the measurement electrodes. This arrangement of two materials is usually called a thermocouple.
The measured Seebeck coefficient is then a contribution from both and can be written as:
SAB=SB-SA={\DeltaVB\over\DeltaT}-{\DeltaVA\over\DeltaT}
Although only relative Seebeck coefficients are important for externally measured voltages, the absolute Seebeck coefficient can be important for other effects where voltage is measured indirectly. Determination of the absolute Seebeck coefficient therefore requires more complicated techniques and is more difficult, but such measurements have been performed on standard materials. These measurements only had to be performed once for all time, and for all materials; for any other material, the absolute Seebeck coefficient can be obtained by performing a relative Seebeck coefficient measurement against a standard material.
A measurement of the Thomson coefficient
l{K}
S(T)=
T | |
\int | |
0 |
{l{K}(T')\overT'}dT'
l{K}
S(T)
l{K}/T
Superconductors have zero Seebeck coefficient, as mentioned below. By making one of the wires in a thermocouple superconducting, it is possible to get a direct measurement of the absolute Seebeck coefficient of the other wire, since it alone determines the measured voltage from the entire thermocouple. A publication in 1958 used this technique to measure the absolute Seebeck coefficient of lead between 7.2 K and 18 K, thereby filling in an important gap in the previous 1932 experiment mentioned above.[5]
The combination of the superconductor-thermocouple technique up to 18 K, with the Thomson-coefficient-integration technique above 18 K, allowed determination of the absolute Seebeck coefficient of lead up to room temperature. By proxy, these measurements led to the determination of absolute Seebeck coefficients for all materials, even up to higher temperatures, by a combination of Thomson coefficient integrations and thermocouple circuits.[6]
The difficulty of these measurements, and the rarity of reproducing experiments, lends some degree of uncertainty to the absolute thermoelectric scale thus obtained. In particular, the 1932 measurements may have incorrectly measured the Thomson coefficient over the range 20 K to 50 K. Since nearly all subsequent publications relied on those measurements, this would mean that all of the commonly used values of absolute Seebeck coefficient (including those shown in the figures) are too low by about 0.3 μV/K, for all temperatures above 50 K.[7]
In the table below are Seebeck coefficients at room temperature for some common, nonexotic materials, measured relative to platinum.[8] The Seebeck coefficient of platinum itself is approximately −5 μV/K at room temperature,[9] and so the values listed below should be compensated accordingly. For example, the Seebeck coefficients of Cu, Ag, Au are 1.5 μV/K, and of Al −1.5 μV/K. The Seebeck coefficient of semiconductors very much depends on doping, with generally positive values for p doped materials and negative values for n doping.
Material | Seebeck coefficient relative to platinum (μV/K) | |
---|---|---|
900 | ||
500 | ||
440 | ||
330 | ||
47 | ||
25 | ||
19 | ||
10 | ||
7.5 | ||
6.5 | ||
6.0 | ||
4.5 | ||
4.0 | ||
3.5 | ||
3.0 | ||
0.6 | ||
0 (definition) | ||
-2.0 | ||
-9.0 | ||
-15 | ||
-35 | ||
-72 |
A material's temperature, crystal structure, and impurities influence the value of thermoelectric coefficients. The Seebeck effect can be attributed to two things:[10] charge-carrier diffusion and phonon drag.
On a fundamental level, an applied voltage difference refers to a difference in the thermodynamic chemical potential of charge carriers, and the direction of the current under a voltage difference is determined by the universal thermodynamic process in which (given equal temperatures) particles flow from high chemical potential to low chemical potential. In other words, the direction of the current in Ohm's law is determined via the thermodynamic arrow of time (the difference in chemical potential could be exploited to produce work, but is instead dissipated as heat which increases entropy). On the other hand, for the Seebeck effect not even the sign of the current can be predicted from thermodynamics, and so to understand the origin of the Seebeck coefficient it is necessary to understand the microscopic physics.
Charge carriers (such as thermally excited electrons) constantly diffuse around inside a conductive material. Due to thermal fluctuations, some of these charge carriers travel with a higher energy than average, and some with a lower energy. When no voltage differences or temperature differences are applied, the carrier diffusion perfectly balances out and so on average one sees no current:
\scriptstyleJ=0
\scriptstyle\sigma
\scriptstyleJ=-\sigma\boldsymbol\nablaV
For the thermoelectric effect, now, consider the case of uniform voltage (uniform chemical potential) with a temperature gradient. In this case, at the hotter side of the material there is more variation in the energies of the charge carriers, compared to the colder side. This means that high energy levels have a higher carrier occupation per state on the hotter side, but also the hotter side has a lower occupation per state at lower energy levels. As before, the high-energy carriers diffuse away from the hot end, and produce entropy by drifting towards the cold end of the device. However, there is a competing process: at the same time low-energy carriers are drawn back towards the hot end of the device. Though these processes both generate entropy, they work against each other in terms of charge current, and so a net current only occurs if one of these drifts is stronger than the other. The net current is given by
\scriptstyleJ=-\sigmaS\boldsymbol\nablaT
\scriptstyle\sigmaS
The processes described above apply in materials where each charge carrier sees an essentially static environment so that its motion can be described independently from other carriers, and independent of other dynamics (such as phonons). In particular, in electronic materials with weak electron-electron interactions, weak electron-phonon interactions, etc. it can be shown in general that the linear response conductance is
\sigma=\intc(E)(-
df(E) | |
dE |
)dE,
\sigmaS=
k\rm | |
-e |
\int
E-\mu | |
k\rmT |
c(E)(-
df(E) | |
dE |
)dE
\scriptstylec(E)
\scriptstylef(E)
is a function peaked around the chemical potential (Fermi level)
- df(E) dE =
1 4k\rmT \operatorname{sech}2\left(
E-\mu 2k\rmT \right)
\mu
3.5k\rmT
\sigma
c(E)=e2D(E)\nu(E)
D(E)
\nu(E)
In materials with strong interactions, none of the above equations can be used since it is not possible to consider each charge carrier as a separate entity. The Wiedemann–Franz law can also be exactly derived using the non-interacting electron picture, and so in materials where the Wiedemann–Franz law fails (such as superconductors), the Mott relations also generally tend to fail.[13]
The formulae above can be simplified in a couple of important limiting cases:
In semimetals and metals, where transport only occurs near the Fermi level and
\scriptstylec(E)
E ≈ \mu\pmk\rmT
\scriptstylec(E)=c(\mu)+c'(\mu)(E-\mu)+O[(E-\mu)2]
S\rm=
| |||||||||||||
-3e |
c'(\mu) | |
c(\mu) |
+O[(k\rmT)3], \sigma\rm=c(\mu)+O[(k\rmT)2].
In the free electron model with scattering, the value of
\scriptstylec'(\mu)/c(\mu)
\scriptstyle1/(k\rmT\rm)
T\rm
\scriptstyleS\rm ≈ \tfrac{\pi2k\rm
The fraction
\scriptstylec'(\mu)/c(\mu)
\scriptstyle\sigma\rm
\scriptstylec'(\mu)/c(\mu)
In semiconductors at low levels of doping, transport only occurs far away from the Fermi level. At low doping in the conduction band (where
\scriptstyleE\rm-\mu\ggk\rmT
\scriptstyleE\rm
\scriptstyle-
df(E) | |
dE |
≈ \tfrac{1}{k\rmT}
-(E-\mu)/(k\rmT) | |
e |
\scriptstylec(E)=A\rm(E-E\rm
a\rm | |
) |
\scriptstyleA\rm
\scriptstylea\rm
S\rm=
k\rm | |
-e |
[
E\rm-\mu | |
k\rmT |
+a\rm+1], \sigma\rm=A\rm(k\rm
a\rm | |
T) |
| ||||
e |
\Gamma(a\rm+1).
\scriptstyle\mu-E\rm\ggkT
\scriptstylec(E)=A\rm(E\rm-
a\rm | |
E) |
S\rm=
k | |
e |
[
\mu-E\rm | |
k\rmT |
+a\rm+1], \sigma\rm=A\rm(k\rm
a\rm | |
T) |
| ||||
e |
\Gamma(a\rm+1).
\scriptstylea\rm
\scriptstylea\rm
In extrinsic (doped) semiconductors either the conduction or valence band will dominate transport, and so one of the numbers above will give the measured values. In general however the semiconductor may also be intrinsic in which case the bands conduct in parallel, and so the measured values will be
S\rm=
\sigma\rmS\rm+\sigma\rmS\rm | |
\sigma\rm+\sigma\rm |
, \sigma\rm=\sigma\rm+\sigma\rm
\scriptstyle\sigmaS2
See main article: Phonon drag. Phonons are not always in local thermal equilibrium; they move against the thermal gradient. They lose momentum by interacting with electrons (or other carriers) and imperfections in the crystal. If the phonon-electron interaction is predominant, the phonons will tend to push the electrons to one end of the material, hence losing momentum and contributing to the thermoelectric field. This contribution is most important in the temperature region where phonon-electron scattering is predominant. This happens for
T ≈ {1\over5}\thetaD
where
\scriptstyle\theta\rm
\scriptstyle\theta\rm/5
This region of the thermopower-versus-temperature function is highly variable under a magnetic field.
The Seebeck coefficient of a material corresponds thermodynamically to the amount of entropy "dragged along" by the flow of charge inside a material; it is in some sense the entropy per unit charge in the material.[19]