Planckian locus explained

In physics and color science, the Planckian locus or black body locus is the path or locus that the color of an incandescent black body would take in a particular chromaticity space as the blackbody temperature changes. It goes from deep red at low temperatures through orange, yellowish, white, and finally bluish white at very high temperatures.

A color space is a three-dimensional space; that is, a color is specified by a set of three numbers (the CIE coordinates X, Y, and Z, for example, or other values such as hue, colorfulness, and luminance) which specify the color and brightness of a particular homogeneous visual stimulus. A chromaticity is a color projected into a two-dimensional space that ignores brightness. For example, the standard CIE XYZ color space projects directly to the corresponding chromaticity space specified by the two chromaticity coordinates known as x and y, making the familiar chromaticity diagram shown in the figure. The Planckian locus, the path that the color of a black body takes as the blackbody temperature changes, is often shown in this standard chromaticity space.

Planckian locus in the XYZ color space

In the CIE XYZ color space, the three coordinates defining a color are given by X, Y, and Z:[1]

XT=\intλX(λ)M(λ,T)dλ

YT=\intλY(λ)M(λ,T)dλ

ZT=\intλZ(λ)M(λ,T)dλ

where M(λ,T) is the spectral radiant exitance of the light being viewed, and X(λ), Y(λ) and Z(λ) are the color matching functions of the CIE standard colorimetric observer, shown in the diagram on the right, and λ is the wavelength. The Planckian locus is determined by substituting into the above equations the black body spectral radiant exitance, which is given by Planck's law:

M(λ,T)=

c1
λ5
1
\exp\left(c2T
{λ

\right)-1}

where:

c1 = 2hc2 is the first radiation constant

c2 = hc/k is the second radiation constantand

M is the black body spectral radiant exitance (power per unit area per unit wavelength: watt per square meter per meter (W/m3))

T is the temperature of the black body

h is the Planck constant

c is the speed of light

k is the Boltzmann constant

This will give the Planckian locus in CIE XYZ color space. If these coordinates are XT, YT, ZT where T is the temperature, then the CIE chromaticity coordinates will be

xT=

XT
XT+YT+ZT

yT=

YT
XT+YT+ZT

Note that in the above formula for Planck's Law, you might as well use c1L = 2hc2 (the first radiation constant for spectral radiance) instead of c1 (the “regular” first radiation constant), in which case the formula would give the spectral radiance L(λ,T) of the black body instead of the spectral radiant exitance M(λ,T). However, this change only affects the absolute values of XT, YT and ZT, not the values relative to each other. Since XT, YT and ZT are usually normalized to YT = 1 (or YT = 100) and are normalized when xT and yT are calculated, the absolute values of XT, YT and ZT do not matter. For practical reasons, c1 might therefore simply be replaced by 1.

Approximation

The Planckian locus in xy space is depicted as a curve in the chromaticity diagram above. While it is possible to compute the CIE xy co-ordinates exactly given the above formulas, it is faster to use approximations. Since the mired scale changes more evenly along the locus than the temperature itself, it is common for such approximations to be functions of the reciprocal temperature. Kim et al. use a cubic spline:[2]

xc=\begin{cases} -0.2661239

109
T3

-0.2343589

106
T2

+0.8776956

103
T

+0.179910&1667K\leqT\leq4000K\\ -3.0258469

109
T3

+2.1070379

106
T2

+0.2226347

103
T

+0.240390&4000K\leqT\leq25000K \end{cases}

yc=\begin{cases} -1.1063814

3
x
c

-1.34811020

2
x
c

+2.18555832xc-0.20219683&1667K\leqT\leq2222K\\ -0.9549476

3
x
c

-1.37418593

2
x
c

+2.09137015xc-0.16748867&2222K\leqT\leq4000K\\ +3.0817580

3
x
c

-5.87338670

2
x
c

+3.75112997xc-0.37001483&4000K\leqT\leq25000K \end{cases}

The Planckian locus can also be approximated in the CIE 1960 color space, which is used to compute CCT and CRI, using the following expressions:[3]

\bar{u}(T)=0.860117757+1.54118254 x 10-4T+1.28641212 x 10-7T2
1+8.42420235 x 10-4T+7.08145163 x 10-7T2
\bar{v}(T)=0.317398726+4.22806245 x 10-5T+4.20481691 x 10-8T2
1-2.89741816 x 10-5T+1.61456053 x 10-7T2

This approximation is accurate to within

\left|u-\bar{u}\right|<8 x 10-5

and

\left|v-\bar{v}\right|<9 x 10-5

for

1000K<T<15000K

. Alternatively, one can use the chromaticity (x, y) coordinates estimated from above to derive the corresponding (u, v), if a larger range of temperatures is required.

The inverse calculation, from chromaticity co-ordinates (x, y) on or near the Planckian locus to correlated color temperature, is discussed in .

Correlated color temperature

The mathematical procedure for determining the correlated color temperature involves finding the closest point to the light source's white point on the Planckian locus. Since the CIE's 1959 meeting in Brussels, the Planckian locus has been computed using the CIE 1960 color space, also known as MacAdam's (u,v) diagram.[4] Today, the CIE 1960 color space is deprecated for other purposes:[5]

Owing to the perceptual inaccuracy inherent to the concept, it suffices to calculate to within 2 K at lower CCTs and 10 K at higher CCTs to reach the threshold of imperceptibility.[6]

International Temperature Scale

The Planckian locus is derived by the determining the chromaticity values of a Planckian radiator using the standard colorimetric observer. The relative spectral power distribution (SPD) of a Planckian radiator follows Planck's law, and depends on the second radiation constant,

c2=hc/k

. As measuring techniques have improved, the General Conference on Weights and Measures has revised its estimate of this constant, with the International Temperature Scale (and briefly, the International Practical Temperature Scale). These successive revisions caused a shift in the Planckian locus and, as a result, the correlated color temperature scale. Before ceasing publication of standard illuminants, the CIE worked around this problem by explicitly specifying the form of the SPD, rather than making references to black bodies and a color temperature. Nevertheless, it is useful to be aware of previous revisions in order to be able to verify calculations made in older texts:[7] [8]

c2

= (ITS-27). Note: Was in effect during the standardization of Illuminants A, B, C (1931), however the CIE used the value recommended by the U.S. National Bureau of Standards, 1.435 × 10−2[9] [10]

c2

= (IPTS-48). In effect for Illuminant series D (formalized in 1967).

c2

= (ITS-68), (ITS-90). Often used in recent papers.

c2

= (CODATA 2010)[11]

c2

= (CODATA 2014)[12] [13]

c2

= (CODATA 2018). Current value, as of 2020.[14] The 2019 redefinition of the SI base units fixed the Boltzmann constant to an exact value. Since the Planck constant and the speed of light were already fixed to exact values, that means that c2 is now an exact value as well. Note that ... doesn't indicate a repeating fraction; it merely means that of this exact value only the first ten digits are shown.

See also

External links

Notes and References

  1. Book: Wyszecki, Günter . Stiles, Walter Stanley . amp . Color Science: Concepts and Methods, Quantitative Data and Formulae . 2E. Wiley-Interscience . 2000 . 0-471-39918-3.
  2. Journal of the Korean Physical Society. 41. 6. December 2002. 865–871. Design of Advanced Color Temperature Control System for HDTV Applications. https://web.archive.org/web/20190303161843/http://pdfs.semanticscholar.org/cc7f/c2e67601ccb1a8fec048c9b78a4224c34d26.pdf. dead. 2019-03-03. Bongsoon Kang. Ohak Moon. Changhee Hong. Honam Lee. Bonghwan Cho. Youngsun Kim. 4489377 .
  3. Color Research & Application. An algorithm to calculate correlated colour temperature. Michael P.. Krystek. 10. 1. January 1985. 38–40. 10.1002/col.5080100109. A new algorithm to calculate correlated colour temperature is given. This algorithm is based on a rational Chebyshev approximation of the Planckian locus in the CIE 1960 UCS diagram and a bisection procedure. Thus time-consuming search procedures in tables or charts are no longer necessary..
  4. Lines of constant correlated color temperature based on MacAdam's (u,v) Uniform chromaticity transformation of the CIE diagram. Kenneth L.. Kelly. JOSA. 53. 8. August 1963. 10.1364/JOSA.53.000999. 999. 1963JOSA...53..999K.
  5. Book: Simons, Ronald Harvey. Lighting Engineering: Applied Calculations. Bean, Arthur Robert . Architectural Press. 0-7506-5051-6. 2001.
  6. Web site: Results of the Intercomparison of Correlated Color Temperature Calculation. 19 June 1999. CORM. Yoshi. Ohno. Jergens, Michael. dead. https://web.archive.org/web/20060930180626/http://cie2.nist.gov/CR3/Documents/Results_CCTcomparison.pdf. 30 September 2006.
  7. Book: Colorimetry: Understanding the CIE System. Janos Schanda. Wiley Interscience. 2007. 3: CIE Colorimetry. 978-0-470-04904-4. 37–46.
  8. Web site: The ITS-90 Resource Site . 2008-02-20 . https://web.archive.org/web/20080221023247/http://www.its-90.com/its-90p4.html . 2008-02-21 . dead .
  9. The Early History of the International Practical Scale of Temperature. J.A.. Hall. 10.1088/0026-1394/3/1/006. Metrologia. 3. 1. 25–28. January 1967.
  10. A table of Planckian radiation. Parry. Moon. March 1948. JOSA. 38. 3. 291–294. 10.1364/JOSA.38.000291. 18903298 .
  11. Web site: CODATA Recommended Values of the Fundamental Physical Constants: 2010. 2012. Peter J.. Mohr . Taylor, Barry N. . Newell, David B..
  12. Mohr. Peter J.. 2016-09-26. CODATA recommended values of the fundamental physical constants: 2014. Reviews of Modern Physics. 88. 3. 035009 . 10.1103/RevModPhys.88.035009. 1507.07956. 2016RvMP...88c5009M. 1115862 .
  13. Mohr. Peter J.. Newell. David B.. Taylor. Barry N.. 2016-11-22. CODATA Recommended Values of the Fundamental Physical Constants: 2014. Journal of Physical and Chemical Reference Data. en. 45. 4. 043102. 10.1063/1.4954402. 0047-2689. 1507.07956. 2016JPCRD..45d3102M .
  14. Web site: 2018 CODATA Value: second radiation constant – The NIST Reference on Constants, Units, and Uncertainty. . 2020-01-17.