ISO 31-10 is the part of international standard ISO 31 that defines names and symbols for quantities and units related to nuclear reactions and ionizing radiations. It gives names and symbols for 70 quantities and units. Where appropriate, conversion factors are also given.

Its definitions include:

QuantityUnitRemarks
NameSymbolDefinitionNameSymbolDefinition
activityAExpectation value of the number of spontaneous nuclear transitions from a particular energy state occurring in an amount of radionuclide in a small time interval, divided by that time intervalbecquerelBq1 Bq = 1/sThe becquerel is a special name for second to the power minus one, to be used as the SI unit of activity.
curie:
1 Ci = 3.7×1010 Bq (exactly)
absorbed doseDFor any ionizing radiation, the mean energy imparted to an element of irradiated matter divided by the mass of this elementgrayGy1 Gy = 1 J/kgThe gray is a special name for joule per kilogram, to be used as the SI unit for absorbed dose.
rad:
1 rad = 0.01 Gy
dose equivalentHProduct of D, Q and N, at the point of interest in tissue, where D is the absorbed dose, Q is the quality factor and N is the product of any other modifying factors
H = D · Q · N
For Q and N, see CIPM, 1984, Recommendation 1 http://www.bipm.fr/en/CIPM/db/1984/1/ and ICRU Report 33 (1980) http://doi.wiley.com/10.1002/jlcr.2580180918
sievertSv1 Sv = 1 J/kgThe sievert is a special name for joule per kilogram, to be used as the SI unit for dose equivalent.
rem:
1 rem = 0.01 Sv