The Feed-Drum[1] is an imperial bass drum with a system of electronic conditioning of the skin conceived by composer Michelangelo Lupone and coproduced between CRM - Centro Ricerche Musicali, Rome and Istituto Gramma in L'Aquila.
Through the principle of feed-back, the signal produced by the excitation of the skin returns to the skin in the form of acoustic pressure. The result is an infinitely sustained sound. The system controls the damping of the movement of the skin, and therefore the decay rate of the sound, and permits isolation of high frequency modes by the combined action of nodes present on the skin and the amount of feed-back input energy.[2] The design on the skin surface is a simplified map of the oscillatory modes based on the Bessel functions. The map was limited to 13 diameters and 8 nodal circles, the latter divided into even semicircles (to the left) and odd semicircles (to the right).[3] See also Skin-Act.
Although the skin of an imperial bass drum allows the excitation of a considerable number of high-frequency modes, their duration in time is not normally appreciable by the listener, apart from the timbric contribution to the attack phase of the sound. The possible variations of the mode of emission, adequate for a sufficient acoustic response of the resonator (shell), are limited and with scarce modulability. The basic frequency, obtained by the tension of the skins, upper and lower, each bound to the edges with 16 mechanical tie rods, is influenced by the non-homogeneous distribution of the tensioning forces which contributes to render complex the spectrum of the real modes.[4]
Experiments were made at the Centro Ricerche Musicali - CRM in Rome[5] [6] and at the Istituto Gramma in L'Aquila with the aim of achieving these objectives:
Traditional bass drums obviously do not provide these characteristics. To explore the timbre richness of the attack phase and isolate the vibrational modes, the makers created a system to electronically manipulate the skin. Through the principle of feedback, the system returns the signal produced by the excitation of the skin back to the skin as acoustic pressure. This produces infinite prolongation of the sound. The system controls the damping the skin, and therefore the decay rate of the sound, and permits isolating high frequency modes by the combined action of the nodes present on the skin and of the amount of feed-back input energy.[7]
The stability of the signal obtained with this conditioning system makes it possible to experiment and design on the skin surface a preliminary simplified map of the oscillatory modes based on the Bessel’s functions. The map is limited to 13 diameters and 8 nodal circles, the latter divided into even semicircles (to the left) and odd semicircles (to the right). Electronic conditioning of the instrument leaves the topology and primary acoustic features unaltered, but increases the scope of the vibrational criteria and control. This made it possible to distinguish the different pitches of various modes, to obtain the emission of long notes, which could be modulated as those emitted by a stretched string, and to adapt the acoustic energy independently of the emitted frequencies.[8]
To maintain agile execution and adequate reproducibility of the phenomena, the first classification of sounds and performance techniques was limited to the use of fingers, hands and arms (Fig. 4). During the composition of Gran Cassa by Michelangelo Lupone, experiments were also made with objects of different shapes and dimensions occupying wider or multiple nodal sections. This increased the sound possibilities. However, the complexity of the vibrational phenomena required analysis of the instrument's mechanical parts to identify and reduce dispersions and non-linear contributions from vibrations of the structural materials and their combinations.[9]
Given these complications, it was decided to plan and realize a new instrument, the Feed-Drum (Fig. 5), for the purpose of not only extending the acoustic possibilities, but also of permitting the ergonomic use of new executive techniques. In particular, the vibrational attitude was transformed by eliminating the lower skin, a decision which simplified the tuning of the instrument’s basic frequency (30 Hz) and reduced the excitation rise time in the upper modes. A synthetic membrane was applied with isotropic characteristics and high flexibility on which the previously described map was drawn, with colors that made the areas of performance more visible. The shell and the tensioning hoop were realized in steel and aluminium; in particular, the tensioning hoop was made stiffer while the height was reduced and the adhesion surface increased. The suspension system was realized in such a way as to separate the Feed-Drum completely from the supporting structure on the ground; all the mechanical parts, which were in contact with one another, were separated by an intermediate layer of antivibrational material.[10]
The behaviour of the Feed-Drum is extremely complex and many of its aspects remain to be clarified. Below are the known elements, those conjectural, and those still undefined.
The oscillation modes of a circular non-rigid membrane—pegged down and stretched along its rim—are known from literature. In a conservative model (that is, without dissipations and acoustic irradiations and therefore “in vacuum”), the oscillation modes of a membrane of radius a have the form in cylindrical coordinates
z(\rho,\phi,\tau)=R(\rho)*\Phi(\phi)*cos(\omega*\tau)
where:
R(\rho)=Jn(m,k\rho)
\Phi(\phi)=A*cos(m*\phi+\phi0)
and where
Jn(m,x)
m*\phi0
Owing to the constraint on the rim,
R(a)=Jn(m,k*a)=0
a
km,n=Rm,n/a
Rm,n
m,Jn(m,x)
Hence (1) becomes
zm,n(\rho,\phi,\tau)=Am,n*Jn(m,km,n\rho)*cos(m*\phi+
0) | |
\phi | |
m,n |
Determination of the wave number is therefore possible by determining the roots of the Bessel function of the first kind. Once the roots and wave numbers are determined, the angular frequencies peculiar to the modes are given by:
\omegam,n=km,n*c
c=\sqrt{T/\sigma}
T
\sigma
c
v1
(0,1)
R0,1=2.405
c=\tfrac{2*\pi*v1
For the Feed-Drum,
a=0.51m
v1=30Hz
c=40m/s
Irrespective of the order of the Bessel functions, the root base tends to
\pi
m → infty
Calculations of the frequencies for the modes up to 5 octaves above the “basic frequency” (960 Hz for the Feed-Drum) gives the following distributions of frequencies and modal density:
The index
m
n
Excitation of the membrane is via a loudspeaker (Ø = 45 cm.) and an 11 cm-long wave guide (designed to convey maximum acoustic pressure between the center and 1/3 of the radius); that is, fairly short as far as the form factor is concerned. It proved fairly easy to obtain, in addition to the 30 Hz basic frequency, the 68.9 Hz frequency corresponding to the mode (0,2). It was on the contrary impossible to obtain the frequency of 47.8 Hz corresponding to the mode (1,1). At these frequencies, the behavior of the air excited by the loudspeaker can presumably be schematized with a piston motion, which exercises an almost uniform pressure on the membrane. A uniform excitation is poorly compatible with the modal form (1,1). The loudspeaker was driven by an electric power signal, generated by a feed-back system that sampled the signal issued by a piezoceramic sensor placed on the rim and detecting deflection of the membrane. In this way a “multimodal” oscillator was obtained generating a feed-back on a resonant element, the membrane. The loop gain was controllable by a pedal.[11]
Intonation is through the combined action of the negative feed-back gain and of the pressure on one or two points of a nodal line. The effect of the pressure can be schematized in a first approximation as dual: on one hand the introduction of a constraint on the pressure points, on the other a shift of the “work point” of the membrane around a slightly higher tension, and therefore an increase of the transverse wave velocity
c
The apposition of constraint points (z = 0) has the effect, as a rule, of inhibiting every mode which has no set of nodal lines passing through all the aforesaid points, not even with an opportune choice of
\phi0
For example, pressing the center of the membrane makes all the modes with
m=0
m\geq1
In theory, pressure on any two points of the membrane could create constraints incompatible with any mode.
However, all these considerations are better limited to modes of relatively low order. In fact it can be presumed that the approximation of the non-rigid membrane results less valid with the increase of the mode order, since the node base tends to become comparable with the thickness of the membrane itself.There are also other considerations. The classic equation of the membrane generally used for obtaining the modes is entirely conservative and does not take into account either dissipation due to internal friction or irradiation. The latter both being mechanisms that dampen the partials, causing their decay in the absence of an exciting force. A symbolical solution of the equation corresponding to the vibro-acoustic movement described is definitely impossible, even if greatly simplifying hypotheses are adopted. It is possible to solve it with numerical methods (such as FEM, BEM, etc.) but even in this case—if acoustic-elastic coupling and internal dissipations of the membrane are taken into account—the problem remains delicate, and results must be verified experimentally. However, even in the absence of a solution, it is possible to note that decay of the partials is connected with the merit factor (Q) of their resonance, and provokes a widening of the spectral line—always more marked the more the relative mode is damped. The internal frictions are proportional to the velocity of variation of the local curvature, which increases with the frequency. It can therefore be presumed that, similarly to stretched strings, damping of the modes increases with their frequency. Consequently, in the upper spectral areas, where the modes are close together and massed (see Figs. 9 & 10), the transfer function of the membrane is more continuous than discrete, with moderate peaks on the modal frequencies. In these areas the modes which can be excited are less precisely definable and depend on the loop gain and on the frequency characteristics of the negative feedback electronic circuit. Conversely, the passage from one mode to another of adjacent frequency has little influence on the resultant frequency. Construction of a future improved map for excitation of modes must therefore foresee a judicious choice of the pairs of points which offer the most significant discrimination between modes.In addition, the modal frequencies should be verified experimentally, since it can be presumed that the frequencies of some modes deviate from their nominal values owing to the presence of the actuator with relative wave guide which has a beam width equal to 1/3 of the membrane diameter. The measurement of these deviations cannot be determined reliably with theoretical considerations, since the overall model is too complex and can only be solved (as already shown) with numerical methods.
The trials carried out to date with composers and percussionists stimulated suggestions for extending the control criteria, the use of special strikers of various forms and dimensions, and the application of independent hand techniques.[12] Subsequent developments will principally concern ergonomic aspects, with the compilation of more precise nodal maps, of simpler and immediate use. In addition, improvements are quite conceivable in the electronic conditioning system and in its operation for the purpose of improving controllability of the emission of high overtones.[13]