Electrical resistance heating explained

Electrical resistance heating should not be confused with Electric heating.

Electrical resistance heating (ERH) is an intensive Latin: [[in situ]] environmental remediation method that uses the flow of alternating current electricity to heat soil and groundwater and evaporate contaminants.[1] Electric current is passed through a targeted soil volume between subsurface electrode elements. The resistance to electrical flow that exists in the soil causes the formation of heat; resulting in an increase in temperature until the boiling point of water at depth is reached. After reaching this temperature, further energy input causes a phase change, forming steam and removing volatile contaminants. ERH is typically more cost effective when used for treating contaminant source areas.

Technology

Electrical resistance heating is used by the environmental restoration industry for remediation of contaminated soil and groundwater. ERH consists of constructing electrodes in the ground, applying alternating current (AC) electricity to the electrodes and heating the subsurface to temperatures that promote the evaporation of contaminants. Volatilized contaminants are captured by a subsurface vapor recovery system and conveyed to the surface along with recovered air and steam. Similar to Soil vapor extraction, the air, steam and volatilized contaminants are then treated at the surface to separate water, air and the contaminants. Treatment of the various streams depends on local regulations and the amount of contaminant.

Some low volatility organic contaminants have a short hydrolysis half-life For contaminants like these, i.e. 1,1,2,2-Tetrachloroethane and 1,1,1-trichloroethane, hydrolysis can be the primary form of remediation. As the subsurface is heated the hydrolysis half-life of the contaminant will decrease as described by the Arrhenius equation. This results in a rapid degradation of the contaminant. The hydrolysis by-product may be remediated by conventional ERH, however the majority of the mass of the primary contaminant will not be recovered but rather will degrade to a by-product.

There are predominantly two electrical load arrangements for ERH: three-phase and six-phase. Three-phase heating consists of electrodes in a repeating triangular or delta pattern. Adjacent electrodes are of a different electrical phase so electricity conducts between them as shown in Figure 1. The contaminated area is depicted by the green shape while the electrodes are depicted by the numbered circles.

Six-phase heating consists of six electrodes in a hexagonal pattern with a neutral electrode in the center of the array. The six-phase arrays are outlined in blue in Figure 2 below. Once again the contaminated area is depicted by the green shape while the electrodes are depicted by the numbered circles. In a six-phase heating pattern there can be hot spots and cold spots depending on the phases that are next to each other. For this reason, six-phase heating typically works best on small circular areas that are less than 65 feet in diameter.

ERH is typically most effective on volatile organic compounds (VOCs). The chlorinated compounds perchloroethylene, trichloroethylene, and cis- or trans- 1,2-dichloroethylene are contaminants that are easily remediated with ERH. The table shows contaminants that can be remediated with ERH along with their respective boiling points. Less volatile contaminants like xylene or diesel can also be remediated with ERH but energy requirements increase as the volatility decreases.

List of compounds that can be remediated with ERH
ChemicalMolecular Weight (g)Boiling Point (°C)
1,1,1-trichloroethane133.474
1,1,2-trichloroethane133.4114
1,1-dichloroethane9957
1,1-dichloroethene9732
1,2-dichloroethane9984
1,2-dichloropropane167.997
benzene78.180
carbon tetrachloride153.877
chlorobenzene112.6132
chloroform119.462
cis-1,2-dichloroethyene9760
dibromoethane187.9132
ethylbenzene106.2136
1,1,2-Trichloro-1,2,2-trifluoroethane187.448
gasoline100100
methylene chloride/dichloromethane84.941
4-methyl-2-pentanone/methyl isobutyl ketone100.2117
2-methoxy-2-methylpropane/methyl tert-butyl ether88.155
perchloroethylene165.8121
trichloroethene131.587
tert-butyl alcohol74.183
toluene92.1111
trans-1,2-dichloroethene9748
vinyl chloride62.5-14
xylene106.2140

Electrode spacing and operating time can be adjusted to balance the overall remediation cost with the desired cleanup time. A typical remediation may consist of electrodes spaced 15 to 20 feet apart with operating times usually less than a year. The design and cost of an ERH remediation system depends on a number of factors, primarily the volume of soil/groundwater to be treated, the type of contamination, and the treatment goals. The physical and chemical properties of the target compounds are governed by laws that make heated remediations advantageous over most conventional methods. The electrical energy usage required for heating the subsurface and volatilizing the contaminants can account for 5 to 40% of the overall remediation cost.

There are several laws that govern an ERH remediation. Dalton’s law governs the boiling point of a relatively insoluble contaminant. Raoult’s law governs the boiling point of mutually soluble co-contaminants and Henry’s law governs the ratio of the contaminant in the vapor phase to the contaminant in the liquid phase.

Dalton's law

For mutually insoluble compounds, Dalton's law states that the partial pressure of a non aqueous phase liquid (NAPL) is equal to its vapor pressure, and that the NAPL in contact with water will boil when the vapor pressure of water plus the vapor pressure of the VOC is equal to ambient pressure. When a VOC-steam bubble is formed the composition of the bubble is proportional to the composite’s respective vapor pressures.

Raoult's law

For mutually soluble compounds, Raoult's law states that the partial pressure of a compound is equal to its vapor pressure times its mole fraction. This means that mutually soluble contaminants will volatilize slower than if there was only one compound present.

Henry's law

Henry's law describes the tendency of a compound to join air in the vapor phase or dissolve in water. The Henry’s Law constant, sometimes called coefficient, is specific to each compound and depends on the system temperature. The constant is used to predict the amount of contaminant what will remain in the vapor phase (or transfer to the liquid phase), upon exiting the condenser.

Recent Innovations in ERH

Significant ERH technological advancements have occurred over the last five years. Three areas of focus have been: bedrock remediation, 1,4-dioxane and other emerging contaminants, and controlled low temperature heat to enhance other remedial or natural processes.

Bedrock Treatment

ERH has been used for over 15 years for treatment of unconsolidated soils in both the vadose and saturated zones. Recent advancements and results show that ERH can be an effective treatment method for bedrock. At an ERH site, the primary electrical current path is on the thin layer of water immediately adjacent to the soil or rock grains. Little current is carried by the water in the pore volume. It is not the pore fluid that dominates the electrical conductivity; it is the grain wetting fluid that dominates the electrical conductivity. Sedimentary rock will typically possess the thin layer of water required for current flow. This means ERH can effectively be used for treatment of sedimentary bedrock, which typically has significant primary porosity.

1,4-Dioxane

1,4-dioxane is a recently-identified contaminant of concern. The regulatory criteria for 1,4-dioxane is constantly changing as more is learned about this contaminant. 1,4-dioxane has a high solubility in water and a low Henry's Law constant which combine to present complex challenges associated with remediation. At ambient conditions, the physical properties of 1,4-dioxane indicate air stripping is not an efficient treatment mechanism. Recent ERH remediation results indicate that ERH creates conditions favorable for treatment. ERH remediation involves steam stripping, which historically had not been investigated for 1,4-dioxane. At ERH sites, steam stripping was observed to effectively transfer 1,4-dioxane to the vapor phase for subsequent treatment. 99.8% reductions (or greater) in 1,4-dioxane concentrations in groundwater have been documented on recent ERH remediation. Monitoring of the above grade treatment streams indicates that 95% of 1,4-dioxane remained in the vapor stream after removal from the subsurface. Furthermore, granular activated carbon has proven to be an effective 1,4-dioxane vapor treatment method.

Controlled Low Temperature Heating

Volatilization is the primary removal mechanism on most ERH sites. However, ERH can also be used to enhance other processes, some naturally occurring, to reduce the cost for treatment of a plume. ERH can be used to provide controlled low temperature heating for projects with remediation processes that do not involve steam stripping. "Low temperature heating" refers to the targeting of a subsurface temperature that is less than the boiling point of water. Examples of low temperature ERH include heat-enhanced bioremediation, heating the subsurface to temperatures above the solubility of dissolved gasses to induce VOC stripping (most notably carbon dioxide ebullition), heat enhanced in situ chemical oxidation (especially for persulfate activation), and heat-enhanced reduction (such as with iron-catalyzed reactions). ERH low-temperature heating can also be used to hydrolyze chlorinated alkanes in-situ at sub-boiling temperatures where hydrochloric acid released during hydrolysis further reacts with subsurface carbonates and bicarbonates to produce carbon dioxide for subsurface stripping of VOCs.

Using low temperature heating coupled with bioremediation, chemical oxidation, or dechlorination will result in increased reaction rates. This can significantly reduce the time required for these remediation processes as compared to a remediation at ambient temperature. In addition, a low temperature option does not require the use of the above grade treatment system for recovered vapors, as boiling temperatures will not be reached. This means less above grade infrastructure and lower overall cost.

When heat is combined with multi-phase extraction, the elevated temperatures will reduce the viscosity and surface tension of the recovered fluids which makes removal faster and easier. This is the original purpose for the development of ERH - to enhance oil recovery (see above).

Weaknesses

Strengths