CGR 0-6-0T | |
Hatnote: | Unless indicated otherwise, data is for a single engine |
Powertype: | Steam |
Designer: | Robert Stephenson and Company |
Builder: | Robert Stephenson and Company |
Serialnumber: | 2257-2258, 2354 |
Buildmodel: | Stephenson's Patent back-to-back |
Builddate: | 1875, 1879 |
Totalproduction: | 3 |
Uicclass: | Cn2t |
Driver: | 2nd coupled axle |
Coupleddiameter: | NaN0NaN0 |
Wheelbase: | 290NaN0 (loco pair) |
Coupled: | 80NaN0 |
Over Couplers: | 21feet |
Height: | 120NaN0 |
Axleload: | 6sigfig=4NaNsigfig=4 |
Locoweight: | 18sigfig=4NaNsigfig=4 |
Fueltype: | Coal |
Pitch: | 60NaN0 |
Fireboxtype: | Round-top |
Boilerpressure: | 1250NaN0 |
Firearea: | 10square feet |
Totalsurface: | 942square feet |
Tubearea: | 850square feet |
Fireboxarea: | 92square feet |
Cylindercount: | Two |
Cylindersize: | 130NaN0 bore 180NaN0 stroke |
Valvegear: | Stephenson |
Coupling: | Johnston link-and-pin |
Tractiveeffort: | 7600lbf @ 75% |
Operator: | Cape Government Railways |
Numinclass: | 3 |
Fleetnumbers: | E5-E7 |
Deliverydate: | 1876, 1879 |
Firstrundate: | 1876 |
Withdrawndate: | 1912 |
Scrapdate: | 1912 |
The Cape Government Railways 0-6-0T back-to-back of 1876 was a South African steam locomotive from the pre-Union era in the Cape of Good Hope.
In 1876 the Cape Government Railways placed a pair of Stephenson's Patent permanently coupled back-to-back locomotives in service on its Eastern System. They worked out of East London in comparative trials with an experimental Fairlie locomotive which was acquired in that same year.
A third single locomotive of the same design was delivered to the Eastern System in 1879.[1]
To meet the requirement for more powerful locomotives on the Eastern System of the Cape Government Railways due to the heavy grades on the mainline which was being built out of East London, a pair of Stephenson's Patent permanently coupled back-to-back locomotives was ordered from Robert Stephenson and Company in 1875, for experimental purposes. The locomotive pair was shipped on the vessel Claremont and arrived in East London on 1 February 1876, numbered E5 and E6 in the Eastern System's number range. A third single locomotive of the same class, numbered E7 and also built by Robert Stephenson, was delivered in 1879.[1] [2]
The principle of using two tank locomotives which are permanently coupled at their cab ends was patented by Robert Stephenson and Company in 1855. The arrangement allowed the two locomotives to be operated by a single crew. Since each locomotive had separate regulators and reversers, they were also able to be used independently.[3]
A similar arrangement was later used with the German-built Zwillinge locomotives which saw service on the military-built narrow gauge Feldbahn railway lines in German South West Africa and other German territories, where pairs of individual locomotives lettered A and B were semi-permanently coupled back-to-back.
The locomotive pair was placed in service between East London and Belstone on the King William's Town line, where they were evaluated during comparative trials with the experimental CGR Fairlie 0-6-0+0-6-0 which was acquired at the same time.[3]
The trials involved running the two types over 321NaN1 of finished track with an allowed time of 2 hours 40 minutes. This required an average speed of 12mph, with no time discount granted for watering stops, stops to allow steam pressure to build up or to attend to mechanical problems. The difference in altitude between the starting and terminal stations was 1624.822NaN2, the sharpest curve was of 50NaN0 radius and the steepest gradient was 1 in 40. Each type took three trial trains, running alternately, and both types were worked by one driver and one fireman throughout the trials.[3]
Like the Fairlie, the back-to-back engines performed well on curves. Unlike the Fairlie, however, any imperfections in the track affected them badly, especially while descending down a decline. The back-to-back engines lurched badly and, going down a decline, the trailing engine tended to jerk the leading engine from side to side so severely that power had to be applied to the leading engine in order to keep it steady.[3]
While the poor quality coal from Indwe and Molteno, with a high ash content and a tendency to clinker, had an equally negative effect on the performance of both types, the Fairlie proved to be more economical on coal and water. Only two men were allowed to be working each type during the trials, but on the back-to-back engines this was found to be insufficient since both men were exhausted after the short 321NaN1 run.[3]
Better results were obtained by separating the back-to-back engines and running them in the conventional double-heading manner with both locomotives facing in the same direction. The downside of this option, however, was that it required two crews.
It was eventually decided to separate the locomotives permanently, equip them with tenders and use them as shunting engines. In this configuration and application they performed well enough to remain in service until they were scrapped in 1912.[3]
No photograph has yet been found of these locomotives.