Amsler grid explained

Amsler grid
Purpose:Used to detect vision problems resulting from damage to the macula or the optic nerve[1]
Test Of:Central visual field

The Amsler grid, used since 1945, is a grid of horizontal and vertical lines used to monitor a person's central visual field. The grid was developed by Marc Amsler, a Swiss ophthalmologist. It is a diagnostic tool that aids in the detection of visual disturbances caused by changes in the retina, particularly the macula (e.g. macular degeneration, Epiretinal membrane), as well as the optic nerve and the visual pathway to the brain. Amsler grid usually help detecting defects in central 20 degrees of the visual field.[2]

In the test, the person looks with each eye separately at the small dot in the center of the grid. Patients with macular disease may see wavy lines or some lines may be missing.

Amsler grids are supplied by ophthalmologists, optometrists or from web sites, and may be used to test one's vision at home.

The original Amsler grid was black and white. A color version with a blue and yellow grid is more sensitive and can be used to test for a wide variety of visual pathway abnormalities, including those associated with the retina, the optic nerve, and the pituitary gland.

History

In 1869, Jacob Hermann Knapp described scotoma and metamorphopsia in traumatic maculopathy with choroidal rupture using horizontal lines. Similarly in 1874, Richard Forster demonstrated metamorphopsia using a square grid.[3]

Swiss ophthalmologist Marc Amsler described the Amsler grid in the year 1945. It was the first functional test proposed to evaluate metamorphopsia.[4] He may have gotten the idea of the grid from Edmund Landolt, who used a similar small card with a grid pattern to be kept in the center of the visual field testing instrument perimeter.

Clinical significance

Amsler grid can be used in detecting central visual field defects in following conditions:

Types

There are 7 types of Amsler grid charts. All charts measure, which when viewed at a distance of from the eye can be used to measure defects in the central 20 degrees of the visual field.

Chart 1

Chart 1 is the basic version, which is the most familiar and widely used chart among all the charts. In this chart the grid consists of 0.5 cm squares (each for 1° visual field), which totally measures 10 cm X 10 cm size. Most commonly grid is in white color with black background. Grid with black lines in white background is also available (see infobox picture).

Chart 2

Chart 2 is similar to chart 1, but it has diagonal cross lines, which assist correct fixation in case of central scotoma.

Chart 3

Chart 3 is also identical to chart 1, but color is red on black. Stimulating long wavelength foveal cones, this type of chart may help in detecting color scotomas and desaturation which may occur in toxic maculopathies, toxic optic neuropathies and pituitary tumors etc.[9]

Chart 4

Chart 4 has no lines, only a random pattern of white dots in black background. It was intended to differentiate areas of scotoma and metamorphopsia.

Chart 5

Chart 5 has central white dot and horizontal white lines on black background 5mm apart, which allow detecting metamorphopsia.

Chart 6

Chart 6 is similar to chart 5, but lines and central dot is in black on white background. The lines near to fixation points are closer than the chart 5.

Chart 7

Chart 7 is similar to chart 1, however central squares are further divided into 0.5 degree squares.

Procedure

See also

External links

Notes and References

  1. Web site: Amsler Grid: A Test for Macular Degeneration and Other Vision Problems . All About Vision . en.
  2. Web site: Richard C. Allen . Amsler Grid Testing . 2017-01-09.
  3. Tripathy . Koushik . Salini . Baby . Amsler Grid . StatPearls . 2020 . StatPearls Publishing.
  4. Midena . Edoardo . Vujosevic . Stela . Metamorphopsia: An Overlooked Visual Symptom . Ophthalmic Research . 2016 . 55 . 1 . 26–36 . 10.1159/000441033 . english . 0030-3747. free . 2434/881140 . free .
  5. Web site: How to Use the Amsler Grid . BrightFocus Foundation . en . 26 May 2015.
  6. Web site: Choroidal Neovascular Membranes: Background, Pathophysiology, Epidemiology . 9 November 2019.
  7. Su . Daniel . Greenberg . Andrew . Simonson . Joseph L. . Teng . Christopher C. . Liebmann . Jeffrey M. . Ritch . Robert . Park . Sung Chul . Efficacy of the Amsler Grid Test in Evaluating Glaucomatous Central Visual Field Defects . Ophthalmology . April 2016 . 123 . 4 . 737–743 . 10.1016/j.ophtha.2015.12.003 . 1549-4713.
  8. Web site: Visual Field Loss - Hemianopsia.net Everything you need to know about Hemianopsia . www.hemianopsia.net . en.
  9. Web site: Amsler grid . Smart Optometry.